OM-492 Page 52
11-3. Grounding When Supplying Building Systems
ST-800 576-B
1
Equipment Grounding
Terminal
2
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
3
Ground Device
Use ground device as stated in
electrical codes.
!
Ground generator to system
earth ground if supplying
power to a premises (home,
shop, farm) wiring system.
!
Also see AWS Safety &
Health Fact Sheet No. 29,
Grounding of Portable And
Vehicle Mounted Welding
Generators.
GND/PE
1
2
2
3
11-4. How Much Power Does Equipment Require?
S-0623
1
Resistive Load
A light bulb is a resistive load and
requires a constant amount of power.
2
Non-Resistive Load
Equipment with a motor is a non-re-
sistive load and requires approxi-
mately six times more power while
starting the motor than when running
(see Section 11-8).
3
Rating Data
Rating shows volts and amperes, or
watts required to run equipment.
Amperes x Volts = Watts
Example 1:
If a drill uses 4.5 am-
peres at 115 volts, calculate its run-
ning power requirement in watts.
4.5 A x 115 V = 520 W
The load applied by the drill is 520
watts.
Example 2:
If three 200 watt flood
lamps are used with the drill from Ex-
ample 1, add the individual loads to
calculate total load.
(3 x 200W) + 520 W = 1120 W
The total load applied by the three
flood lamps and drill is 1120 watts.
VOLTS 115
4.5
60
AMPS
Hz
1
2
3
3
Содержание PipePro 304
Страница 35: ...OM 492 Page 31 SECTION 8 MAINTENANCE AND TROUBLESHOOTING 8 1 Maintenance Label...
Страница 50: ...OM 492 Page 46 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Welding Generator...
Страница 51: ...OM 492 Page 47 212 633 F...
Страница 72: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...
Страница 73: ...TM 188 304 Page 2 Invision 354MP Notes...