7-2. Optional GFCI Receptacles And Circuit Breakers
Ref. ST-207 554-A
!
If unit does not have GFCI
receptacles, use GFCI-pro-
tected extension cord.
Generator power decreases as
weld current increases.
1
120 V 20 A AC GFCI Duplex
Receptacle GFCI-2
2
120 V 20 A AC GFCI Duplex
Receptacle GFCI-3
GFCI-2 and GFCI-3 supply 60 Hz
single-phase power at weld/power
speed. Maximum output from
GFCI-2 or GFCI-3 is 2.4 kVA/kW.
Circuit protection is the same as
standard receptacles.
If a ground fault is detected, the GFCI
Reset button pops out and the circuit
opens to disconnect the faulty equip-
ment. Check for damaged tools,
cords, plugs, etc. connected to the
receptacle. Press button to reset re-
ceptacle and resume operation.
At least once a month, run en-
gine at weld/power speed and
press Test button to verify GFCI
is working properly.
1
2
7-3. Wiring Instructions For Optional 240 Volt, 3-Phase Twistlock Plug (NEMA L15-30P)
Plug2 7/99
−
802 437
1
240 V AC Three-Phase, 30 A,
3P4W Twistlock Plug
2
Load 1 (Brass) Terminal (X)
3
Load 2 (Brass)Terminal (Y)
4
Load 3 (Brass) Terminal (Z)
5
Ground (Green) Terminal (G)
6
Cord Grip
Strip cord jacket back enough to sep-
arate conductors.
Strip conductors enough to make
good contact with plug terminals.
Make plug connections and reinstall
cord grip.
Tighten cord grip assembly screws.
Do not overtighten.
1
2
240V
240V
240V
Tools Needed:
6
3
4
5
Содержание PipePro 304
Страница 35: ...OM 492 Page 31 SECTION 8 MAINTENANCE AND TROUBLESHOOTING 8 1 Maintenance Label...
Страница 50: ...OM 492 Page 46 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Welding Generator...
Страница 51: ...OM 492 Page 47 212 633 F...
Страница 72: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...
Страница 73: ...TM 188 304 Page 2 Invision 354MP Notes...