OM-492 Page 22
5-9. Guidelines For Installing Customer-Supplied Emergency Air Shutdown Valve
A customer-supplied emergency air shutdown
valve can be installed to stop the engine imme-
diately in emergency situations.
These guidelines show the typical installation of
a Gator ESD 175-275-L3 air shutdown valve.
Installation of other air shutdown valves may
differ from that shown. Contact the air shut-
down valve manufacturer or a Factory Autho-
rized Service Agent for additional installation
and operation information.
!
Stop engine, and let cool.
!
Disconnect battery negative (
−
) cable.
Open doors and remove side panels.
1
Air Cleaner
2
2 in (51 mm) Hose Clamp
3
1-3/4 x 2 in (44 x 51 mm) Rubber Hose
4
Air Shutdown Valve
(Gator ESD 175-275-L3)
5
1-3/4 x 16-1/2 in (44 x 419 mm) Flexible
Radiator Hose (NAPA Part No. FM68)
Use thick-walled rubber hose. Do not use
heater hose. (Heater hose could let dirt into
engine.)
6
Engine Air Inlet
7
Shutdown Control
8
42 in (1067 mm) Shutdown Control Cable
(Supplied By Gator)
9
Shutdown Valve Reset Lever
Install components as shown.
Be sure air shutdown valve is installed with air
flow arrow pointing toward air inlet. Use cable
ties to keep air shutdown system components
away from hot or moving parts.
Verify the emergency air shutdown system op-
erates correctly. After testing, use reset lever to
reset air shutdown valve.
Reinstall side panels and close doors.
Reconnect battery negative (
−
) cable.
803 390
1
Mount on lower
front panel
2
3
4
5
7
8
6
7
9
Содержание PipePro 304
Страница 35: ...OM 492 Page 31 SECTION 8 MAINTENANCE AND TROUBLESHOOTING 8 1 Maintenance Label...
Страница 50: ...OM 492 Page 46 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Welding Generator...
Страница 51: ...OM 492 Page 47 212 633 F...
Страница 72: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...
Страница 73: ...TM 188 304 Page 2 Invision 354MP Notes...