OM-4409 Page 42
8-5. Jump Starting Procedure
Connect Cables (Observe
Correct Polarity).
Set Output Selector Switch To
Voltage Of Battery Being
Charged (12 Or 24 Volt).
NOTICE
−
Do not switch under load.
+
−
Start Engine.
Set Process/Contactor Switch To
Any Remote On/Off Switch Required
Position.
Charge battery for 10 minutes before
jump starting battery.
Stop Engine.
Set Ampere Range Switch To
300-Max Position.
NOTICE
−
Do not switch under load.
Press (Close) Remote Momentary-On
Switch While Cranking Engine Of Equip-
ment Being Jump Started. Release Switch
When Equipment Starts. Stop Welding
Generator And Disconnect Cables.
Press (close)
switch only while
cranking engine of
equipment being
started.
Stop Engine.
Disconnect
Cables.
OR
Connect Remote
Control Device
(Momentary-On
Switch).