OM-4409 Page 30
5-10. Connecting To Remote 14 Receptacle RC14
Socket*
Socket Information
24 VOLTS AC
A
24 volts ac. Protected by sup-
plementary protector CB5.
24 VOLTS AC
B
Contact closure to A completes
24 volt ac contactor control
circuit.
C
Output to remote c10
volts dc in MIG or Stick mode;
0 to +10 volts dc in TIG mode.
REMOTE
OUTPUT
D
Remote control circuit common.
OUTPUT
CONTROL
E
DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
OR
115 VOLTS AC
I
115 volts, 10 amperes, 60 Hz
ac. Protected by supplementary
protector CB6.
J
Contact closure to I completes
115 volt ac contactor control
circuit.
803 231
GND
K
Chassis common.
NEUTRAL
G
Circuit common for 24 and 115
volt ac circuit.
*The remaining sockets are not used.
Notes
Содержание Big Blue Air Pak
Страница 25: ...OM 4409 Page 21 4 13 Manufacturing Rating Label...
Страница 47: ...OM 4409 Page 43 SECTION 9 ENGINE GENERATOR MAINTENANCE 9 1 Engine Maintenance Label...
Страница 65: ...OM 4409 Page 61 SECTION 12 AIR COMPRESSOR DIAGRAM 209 059 A Figure 12 1 Circuit Diagram For Air Compressor...
Страница 66: ...OM 4409 Page 62 SECTION 13 CIRCUIT DIAGRAM Figure 13 1 Circuit Diagram For Welding Generator...
Страница 67: ...OM 4409 Page 63 221 915 C...