OM-223 037 Page 31
6-4. Remote Voltage/Amperage Control
1
Remote 14 Receptacle RC14
Connect optional remote control to RC14 (see
Section 5-9).
When a remote control is connected to the
Remote receptacle, the Auto Sense Re-
mote feature automatically switches volt-
age/amperage control to the remote con-
trol. When a device is connected to the Re-
mote receptacle, remote voltage/amper-
age control is always available regardless
of the position of the Process/Contactor
switch.
Ref. 222 875 / Ref 804 068
1
Adjust Optional Remote
Control to 100%
Set V/A Control
To Desired Maximum
Weld Output Using Weld
Meters
Set TIG or STICK Process
In Example:
Min = 20 A DC
Max = 205 A DC
Max (205 A DC)
Min (20 A DC)
Connect Remote
Control To Remote
Receptacle RC14
Adjust Optional Remote
Control to desired
weld output
Weld meters will always
show the combined main
and remote control setting
and machine welds at
nominal output setting of
the meter.
Weld meters show preset
output when not welding.
Set WIRE Process
Connect Remote
Control To Remote
Receptacle RC14
Adjust Optional Remote
Control to desired
weld output