OM-223 037 Page 30
6-3. Process/Contactor Switch
1
Process/Contactor Switch
!
Weld output terminals are ener-
gized when Process/Contactor
switch is in a Weld Terminals Al-
ways On position and the engine
is running.
Use switch to select weld process and
weld output on/off control (see table be-
low).
Place switch in Remote On/Off Switch
Required positions to turn weld output on
and off with a device connected to the
Remote 14 receptacle.
Place switch in Weld Terminals Always
On positions for weld output to be on
whenever the engine is running.
Ref 804 068 / Ref 222 875
1
Process/Contactor Switch Settings
Switch Setting
Process
Output On/Off Control
Switch Setting
Process
Output On/Off Control
Remote On/Off Switch Required
−
TIG
GTAW With HF Unit, Pulsing Device, Or Remote
Control
At Remote 14 Receptacle
Remote On/Off Switch
Required
−
Stick
Stick (SMAW) With Remote On/Off
At Remote 14 Receptacle
Remote On/Off Switch
Required
−
CV Feeder
Using Remote
MIG (GMAW)
w/Constant Speed Feeder
At Remote 14 Receptacle
Weld Terminals Always On
−
Wire
MIG (GMAW)
w/Voltage Sensing Feeder
Electrode Hot
Weld Terminals Always On
−
Stick
Stick (SMAW),
Air Carbon Arc (CAC-A) Cutting And Gouging
Electrode Hot
Weld Terminals Always On
−
TIG
GTAW With HF Unit, Pulsing Device, Or Remote
Control
Electrode Hot
Содержание Big Blue 400 PX
Страница 19: ...OM 223 037 Page 13 3 2 Manufacturer s Rating Label 223 081 A Ref 804 068 E ...
Страница 40: ...OM 223 037 Page 34 8 2 Maintenance Label ...
Страница 50: ...OM 223 037 Page 44 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Welding Generator ...
Страница 51: ...OM 223 037 Page 45 222 966 C ...
Страница 73: ...OM 223 037 Page 67 Notes 229895 MATERIAL THICKNESS GAUGE ...