OM-223 037 Page 19
4-8. Duty Cycle And Overheating
−
60 Hz Operation
217 515
10
15
20
25 30
40 50 60
80
100
CC
CV
1000
800
600
500
400
300
250
200
150
100
WELD
AMPERES
% DUTY CYCLE
100% Duty Cycle At 250 Amperes
Continuous Welding
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
NOTICE
−
Exceeding duty cycle
can damage unit and void warranty.
4-9. AC Generator Power Curve
223 185-A
The ac power curve shows the gen-
erator power in amperes.
0
20
40
60
80
100
120
0
20
40
60
80
100
120
140
AC
V
O
LT
S
0
10
20
30
40
50
60
70
A C A MPERES IN 22 0V MODE
0
40
80
1 20
1 60
2 00
2 40
AC AMPERES IN
MODE
110 V
Содержание Big Blue 400 PX
Страница 19: ...OM 223 037 Page 13 3 2 Manufacturer s Rating Label 223 081 A Ref 804 068 E ...
Страница 40: ...OM 223 037 Page 34 8 2 Maintenance Label ...
Страница 50: ...OM 223 037 Page 44 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Welding Generator ...
Страница 51: ...OM 223 037 Page 45 222 966 C ...