OM-4405 Page 45
C. Standard Auxiliary Power
Trouble
Remedy
No auxiliary power output; weld output
okay.
Reset receptacle circuit breakers.
No auxiliary power or weld output.
Disconnect equipment from auxiliary power receptacles during start-up.
Check fuses F1 and F2, and replace if open (see Section 8-9). Have Factory Authorized Service Agent
check integrated rectifier SR1, capacitor C9, and the rotor.
Reset circuit breaker CB12. Have Factory Authorized Service Agent check diode D1 (CC models) or field
current regulator board PC1 (CC/CV models) (see Section 8-9).
Have Factory Authorized Service Agent check brushes and slip rings, and field excitation circuit.
High output at auxiliary power
receptacles.
Check engine speed, and adjust if necessary.
Have Factory Authorized Service Agent adjust auxiliary power field current resistor R3.
Low output at auxiliary power
receptacles.
Check engine speed, and adjust if necessary.
Check fuse F1, and replace if open (see Section 8-9). Have Factory Authorized Service Agent check inte-
grated rectifier SR1, resistor R3, and capacitor C9.
D. Optional Auxiliary Power Plant
Trouble
Remedy
No or low output at optional auxiliary
power plant/receptacle RC5
(CC/CV models only).
Place Process/Contactor switch in Electrode Hot - Stick position (see Section 6-3).
Reset circuit breaker CB7 (see Section 7-2).
Reset circuit breaker CB5 (see Section 8-9).
Check engine weld/power speed, and adjust if necessary (see Section 8-5).
Have Factory Authorized Service Agent check brushes and slip rings, and field current regulator board
PC1.
High output at optional auxiliary power
plant/receptacle RC5 (CC/CV models
only).
Check engine weld/power speed, and adjust if necessary (see Section 8-5).
Have Factory Authorized Service Agent check field current regulator board PC1.
Erratic output at optional auxiliary power
plant/receptacle RC5 (CC/CV models
only).
Have Factory Authorized Service Agent check brushes and slip rings, and field current regulator board
PC1.
E. Engine
Trouble
Remedy
Engine will not crank.
Check battery, and replace if necessary.
Check battery connections and tighten if necessary.
Circuit breaker CB10 may be open. CB10 automatically resets when fault is corrected (see Section 8-9).
Have Factory Authorized Service Agent check engine wiring harness and components.
Check engine wiring harness plug connections.
Have Factory Authorized Service Agent check Engine Control switch S1.
Содержание Big 40 WG
Страница 29: ...OM 4405 Page 25 Notes...
Страница 37: ...OM 4405 Page 33 SECTION 8 MAINTENANCE TROUBLESHOOTING 8 1 Maintenance Label...
Страница 51: ...OM 4405 Page 47 Notes...
Страница 52: ...OM 4405 Page 48 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For CC Welding Generator...
Страница 53: ...OM 4405 Page 49 201 991 A...
Страница 54: ...OM 4405 Page 50 Figure 9 2 Circuit Diagram For CC CV Welding Generator...
Страница 55: ...OM 4405 Page 51 201 992 A...
Страница 63: ...OM 4405 Page 59 Notes...