OM-201 540 Page 44
7-12. Network And Module Status LED’s
A.
Network Status LED’s
The following are network status LED’s:
LED1 on the UIM circuit board
LED4 on the WFM and PCM circuit boards
LED30 on the AIM circuit board.
Status
Diagnosis
Off
The circuit board is not on-line with the network or there is no power applied to the circuit board.
Green
The circuit board is operating normally and the on-line connection is made with the network.
Flashing Green
The circuit board is wait for an on-line connection to be made with the network.
Red
The circuit board has encountered a communication link failure with the network. Check DeviceNet cable connections. Verify
dip switch positions according to Sections 1-2 and 1-3. Replace circuit board if necessary.
B.
Module Status LED’s
The following are module status LED’s:
LED2 on the UIM circuit board
LED3 on the WFM and PCM circuit boards
LED31 on the AIM circuit board.
Status
Diagnosis
Off
There is no power applied to the circuit board or the board software is not executing its functions.
Green
The circuit board is operating normally.
Flashing Red
The circuit board has encountered a recoverable fault. Wait or cycle power to clear fault.
Red
The circuit board has encountered an unrecoverable fault.
Содержание Auto Axcess 675
Страница 14: ...OM 201 540 Page 10...
Страница 50: ...OM 201 540 Page 46 SECTION 8 ELECTRICAL DIAGRAMS Figure 6 1 Circuit Diagram For Welding Power Source 1 Of 2...
Страница 51: ...OM 201 540 Page 47 198 992 G Part 1 Of 2...
Страница 52: ...OM 201 540 Page 48 Figure 6 2 Circuit Diagram For Welding Power Source 2 Of 2...
Страница 53: ...OM 201 540 Page 49 198 992 G Part 2 Of 2...
Страница 54: ...OM 201 540 Page 50 Figure 6 3 Circuit Diagram For 72 Pin Robot Interface...
Страница 55: ...OM 201 540 Page 51 219 266 C...
Страница 56: ...OM 201 540 Page 52 Figure 6 4 Circuit Diagram For Peripheral Motor Interface...
Страница 57: ...OM 201 540 Page 53 219 267 B...
Страница 65: ...Notes...
Страница 66: ...Notes...