OM-201 540 Page 14
Ref. 802 915-A
1
115 V 10 A AC Receptacle RC2
Receptacle supplies 60 Hz
single-phase power. Maximum output
from RC2 is limited by supplementary
protector CB1 to 10 amps.
2
Supplementary Protector CB1
3
Supplementary Protector CB2
CB1 protects 115 volt receptacle RC2
from overload. If CB1 opens, RC2 does
not work.
CB2 protects the wirefeed motor from
overload. If CB2 opens, the wirefeeder
does not work.
.
Press button to reset breaker. If
breaker continue to open, contact a
Factory Authorized Service Agent.
4
Wirefeed/Gas Receptacle RC8
Use receptacle to connect gas and
motor control cable to power source
(see Sections 3-6 and 8 for additional
information).
5
Peripheral Receptacle RC25
Receptacle provides connection to
touch sensor, water flow switch, jog +/−,
and I/O relay contacts circuitry (see
Section 3-10).
6
Robot Interface Receptacle RC72
Use receptacle to connect robot
input/output cable (see Sections 3-6
and 8 for additional information).
2
3
3-7.
Rear Panel Receptacles And Supplementary Protectors
1
6
4
5
Содержание Auto Axcess 675
Страница 14: ...OM 201 540 Page 10...
Страница 50: ...OM 201 540 Page 46 SECTION 8 ELECTRICAL DIAGRAMS Figure 6 1 Circuit Diagram For Welding Power Source 1 Of 2...
Страница 51: ...OM 201 540 Page 47 198 992 G Part 1 Of 2...
Страница 52: ...OM 201 540 Page 48 Figure 6 2 Circuit Diagram For Welding Power Source 2 Of 2...
Страница 53: ...OM 201 540 Page 49 198 992 G Part 2 Of 2...
Страница 54: ...OM 201 540 Page 50 Figure 6 3 Circuit Diagram For 72 Pin Robot Interface...
Страница 55: ...OM 201 540 Page 51 219 266 C...
Страница 56: ...OM 201 540 Page 52 Figure 6 4 Circuit Diagram For Peripheral Motor Interface...
Страница 57: ...OM 201 540 Page 53 219 267 B...
Страница 65: ...Notes...
Страница 66: ...Notes...