OM-188 304 Page 18
4-7. Connecting 3-Phase Input Power
2/04 - Ref. 802 136-A / 801 192
!
Installation must meet all National
and Local Codes
−
have only quali-
fied persons make this installation.
!
Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit.
!
Always connect green or green/
yellow conductor to supply
grounding terminal first, and never
to a line terminal.
.
The Auto-Link circuitry in this unit au-
tomatically links the power source to
the primary voltage being applied. A
230/460 unit can be connected to ei-
ther 230 or 460 VAC input power. A
460/575 model can be connected to
either 460 or 575 VAC input power.
For Three-Phase Operation
1
Input Power Cord.
2
Disconnect Device (switch shown in
the OFF position)
3
Green Or Green/Yellow Grounding
Conductor
4
Disconnect Device Grounding
Terminal
5
Input Conductors (L1, L2 And L3)
6
Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1, L2, and L3
to disconnect device line terminals.
7
Overcurrent Protection
Select type and size of overcurrent protec-
tion using Section 4-5 (fused disconnect
switch shown).
Close and secure door on disconnect
device. Remove lockout/tagout device,
and place switch in the On position.
= GND/PE Earth Ground
L1
2
1
L2
L3
3
3
4
5
6
7
Tools Needed:
Содержание 230Volt
Страница 4: ......
Страница 14: ...OM 188 304 Page 10...
Страница 30: ...OM 188 304 Page 26 5 8 How Manual Pulsed MIG Waveform Components Affect Arc And Burn Off Rate...
Страница 41: ...OM 188 304 Page 37 206 283 A Figure 8 2 Circuit Diagram For Welding Power Source 460 575 Volt Models...
Страница 45: ...Notes 229895 MATERIAL THICKNESS GAUGE...
Страница 46: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...