OM-188 304 Page 15
4-3. Remote 14 Receptacle Information
Socket*
Socket Information
A
J
24 VOLTS AC
A
24 volts ac. Protected by circuit breaker CB2.
A
J
B
K
I
C L N
H
24 VOLTS AC
B
Contact closure to A completes 24 volts ac
contactor control circuit.
C L N
H
D M
G
F
115 VOLTS AC
I
115 volts ac. Protected by circuit breaker CB1.
E
F
115 VOLTS AC
J
Contact closure to I completes 115 volts ac
contactor control circuit.
C
Output to remote control; +10 volts dc.
REMOTE
OUTPUT
D
Remote control circuit common.
OUTPUT
CONTROL
E
0 to +10 volts dc input command signal from
remote control.
A/V
F
Current feedback; +1 volt dc per 100 amperes.
A/V
AMPERAGE
VOLTAGE
H
Voltage feedback; +1 volt dc per 10 output recep-
tacle volts.
GND
G
Circuit common for 24 and 115 volts ac circuits.
GND
K
Chassis common.
*The remaining sockets are not used.
4-4. Optional 115 Volt AC Duplex Receptacle And Circuit Breakers
ST-801 245-A
1
115 V 10 A AC Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 4-3).
2
Circuit Breaker CB1
CB1 protects duplex receptacle
and 115 volt ac portion of Remote
14 receptacle from overload.
3
Circuit Breaker CB2
CB2 protects 24 volt ac portion of
Remote 14 receptacle from
overload.
Press button to reset breaker.
2
3
1
Содержание 230Volt
Страница 4: ......
Страница 14: ...OM 188 304 Page 10...
Страница 30: ...OM 188 304 Page 26 5 8 How Manual Pulsed MIG Waveform Components Affect Arc And Burn Off Rate...
Страница 41: ...OM 188 304 Page 37 206 283 A Figure 8 2 Circuit Diagram For Welding Power Source 460 575 Volt Models...
Страница 45: ...Notes 229895 MATERIAL THICKNESS GAUGE...
Страница 46: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...