OM-188 304 Page 20
5-2. Meter Functions
.
The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode
Meter Reading At Idle
Meter Reading While Welding
MIG
Preset Volts
Blank
V
A
24.5
Actual Volts
Actual Amps
V
A
24.5
250
Pulsed
MIG
Blank
Pulse Display
V
Trim
50
Actual Volts
Actual Amps
V
A
24.5
250
Stick
−
Contactor Remote
Blank
Preset Amps
V
A
85
Actual Volts
Actual Amps
V
A
24.5
85
Stick
−
Contactor ON
Actual Volts (OCV)
Preset Amps
V
A
80.0
85
Actual Volts
Actual Amps
V
A
24.5
85
Manual
Pulse
Pulses Per Second
V
A
PPS
200
Actual Volts
Actual Amps
V
A
24.5
85