45
Installation
Synchronize Remote Control
The receiver and the handset of the remote control
system must be initially synchronized before the
first use.
1. Insert
alkaline
batteries in the remote control
receiver and handset. The receiver is located left
of the control valve under the burner module.
2. With a sharp object, press and hold the receiver’s
reset button until you hear one short and one long
beeps. Release the reset button after the second
beep.
3. Within the subsequent 20 seconds, press the small
fl ame button ( ) on the remote handset until you
hear two short beeps confi rming the sychronization
is set.
This is a one time setting only and is not required when
changing the batteries in the remote receiver. The
remote control system is now ready to use.
Air Shutter
Check Operation
Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 11–15.
Adjust Aeration (if necessary)
Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. The burner
is equipped with an adjustable shutter to control
primary aeration. See the fi gures below. The shutter is
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
Flashback shield
(propane only)
Air Shutter Slider
(propane gas)
Open
Close
Propane gas
Open
Open
Close
Close
Natural gas
Air Shutter
Slider & Cover
(natural gas)
Depending of fuel bed used, altitude and other
considerations, the fl ame picture may be improved by
adjusting the aeration. The need for adjustment should
be determined only by operating the appliance with the
fuel bed and window installed and evaluating the fl ame
picture after a 15-minute warm-up.
Increasing aeration
will cause the fl ames to appear
more transparent and blue making the ceramic logs
glow more.
Decreasing aeration
will cause the fl ames to appear
more yellow or orange making the ceramic logs glow less.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.