5
Error codes
When using the MultiFeeder, the following error codes
are available on the SIGMA
2
:
is displayed when the communication
between the MultiFeeder and the
SIGMA
2
is lost.
is displayed when controlling the motor is
not running properly.
is displayed when the motor is
overloaded.
Gas control fault
(option):
This icon can only be shown in case a
gas control kit has been mounted. Gas fault is due to a
to low or high pressure on the gas flow.
Make sure that the pressure on the gas flow is higher
than 2 bar and less than 6 bar, corresponding to
5 l/min and 27 l/min.
The fault is disconnected at 27 l/min.
Technical data
Wire feed speed
0.5-30 m/min
Torch connection
EURO
Wire diameter
0.6-1.4 mm
Gas pressure max.
0.5 MPa (5.0 bar)
Dimensions (HxWxL)
27,6x21,1x27,6 cm
Weight
9 kg
Software
The software is placed on a SD card which must
contain the folders and the file as shown below. The
folder names must be saved in BIG letters and with
the original names.
Software reading
Remove the left side plate on the Multifeeder
(must be carried out by electrically skilled
person).
Insert the SIGMA SD-card in the card reader at
the PCB 71613658 inside the Multifeeder-unit.
Turn on the machine.
Wait until the LED at the Multifeeder-unit starts
flashing.
Turn off the machine and remove the SD card.
The machine is now ready for use.
Содержание MultiFeeder
Страница 1: ...MultiFeeder for SIGMA2 Instruction manual Valid from 2020 week 19 50173746 E ...
Страница 2: ......
Страница 7: ...Fig 1 MultiFeeder PCB 71613658 with configuration ...
Страница 8: ...8 ...
Страница 9: ...9 Reservedelsliste Spare parts list Ersatzteilliste Liste des pièces de rechange ...
Страница 15: ......