8.8
Removal of vaporizer liquid
For shipment of the Lötstar unit, and for particular maintenance
works, remove all vaporizer liquid from the unit.
Dispose of the residual vaporizer liquid as described in
section
9.3.
Caution when handling vaporizer liquid! Risk of fire and
explosion due to ignition sources and electrostatic charging!
When handling vaporizer liquid keep away from any ignition
sources!
Avoid electrostatic discharging!
Touch the cap nuts on the holding angle pieces of the top part
with both hands for a short period of time before you open the
vaporizer glass container. This will branch off any possible
electrostatic charging of the operator without any risk!
1. Switch off the gas production at the
on/off
key
I/O
at the
operating panel.
2. Unscrew the fastening ring by turning it to the left (
see
illustration 8.1.3.D
.).
3. Remove the vaporizer glass. Move the complete top part
sideways to facilitate removal of the vaporizer glass.
4. Remove the vaporizer liquid.
6. Fill the vaporizer liquid into a specially marked tank and
store out of reach of unauthorized persons, in particular of
children. Or dispose of the vaporizer liquid as described in
section 9.3
.
5. Remount the vaporizer glass by screwing the fastening ring
back to the right (
see illustration 8.1.3.E
.).
WARNING!
How to proceed