Wireless DA-600 and DA-605 Drive-Alert Control Panel Installation Guide

The 

DA-600 Drive-Alert

 has an internal piezo electric whistle inside the Control Panel as the audible-alert.  The whistle may be 

switched off if desired.  The whistle and the whistle switch can be seen on the top of the DA-600 Control Panel.

 

DA-600

 Control Panel front view  

 

 

 

         top view

The 

DA-605 Drive-Alert’s

 Control Panel/Receiver board is the same as the DA-600. However, the DA-605 does not have an 

internal whistle, nor a whistle switch. The advantage of the DA-605 over the DA-600 is the DA-066MP Wireless Chime Transmitter 
which activates DA-078 remote chimes as an alert.  Unlimited DA-078 Plug-in Chimes may be used, each chime is activated by a 
radio signal from the DA-066MP attached to the control panel. These chimes can be used up to 100’ away from the control panel. 
As stated, the DA-078 plugs into any standard wall outlet.  The DA-066MP can be seen on top of the DA-605 Control Panel.

 

DA-605

 Control Panel front view  

 

 

 

          top view

The relay contacts on the terminal board are Form C dry contacts.   These relay contacts may be supplied with 24 or 5 volts DC with 
the addition of a jumper from the needed voltage to the C terminal.  The Control Panel will operate any of Mier’s Drive-Alert 
accessories listed on the “Accessories” pages of this manual. It can also be used to control other external bells, surveillance systems, 
signs, gates and relays.  An adjustable time control provides 2 to 12 seconds of relay closer for each vehicle detected. 

CONTROL PANEL/RECEIVER INSTALLATION

: (

Sensor/Transmitter installation are on pages 5-7

The Control Panel/Receiver is to be mounted indoors, 4-6 feet above ground level, where 110 volts AC power is available.  To        
maximize transmitter reception, the flexible antenna is to be at least 12 inches from any metal pipes, power conduits, breaker boxes, 
etc.   Simply plug the Control Panel/Receiver into a standard wall outlet, where the signal from the Sensor/Transmitter can reach it. 

For extended ½-mile range reception, or when a Control Panel must be mounted in a basement,

 the DA-660 Long-Range Reception 

Booster Antenna accessory can be used by simply removing the standard antenna and attaching coax cable and the DA-660.  (

see 

the Long Range Options page

)

DA-600 Drive-Alert

 has a WHISTLE ON-OFF SWITCH on top of the Control Panel.

DA-605 Drive-Alert 

has a remote chime with volume control.  Plug in the DA-078 Remote Chime(s) in the area(s) of the house 

where an alert is desired.  For all options and operation instructions of the chimes, see the instructions enclosed with the chimes.  
The DA-078 chimes may be located in multiple rooms and locations, and the DA-605 can trigger an unlimited number of chimes 
within 100+ feet of the DA-605 Control Panel.  If chimes are desired even further away, see the DA-REPEATER and DA-100CP acces-
sories.

Testing the communication between a DA-605 Control Panel and the Chimes is accomplished by pushing the DA-066MP Test/Call 
Push-Button attached to the top of the Control Panel, and 

holding the button down for AT LEAST two (2) seconds

, which sends a 

315 MHz radio signal to trigger the two-tone (ding-dong) remote DA-078 chimes.  As stated, this signal will reach at least 100 feet to 
the chimes.  The chimes can be tested independent of the Drive-Alert Sensor/Transmitter.

The DA-066MP Chime Transmitter, and the DA-078 

chime codes are preset.

  

Do not change the codes.

800-473-0213        ~        [email protected]        ~        www.mierproducts.com

Содержание DA-600

Страница 1: ...ering monitored area s 2 A control panel up to 1000 feet away receives a signal from the sensor and triggers an alert inside the home or business booster antenna increases range to 3 4 mile 3 Add remote plug in chimes in the front room basement upstairs back yard by the pool or in other buildings 4 Add a Timer Control to turn on outdoor and in door lights to warn strangers or welcome friends 5 Act...

Страница 2: ...allations page Use of an unlimited number of Mier Wireless Transmitters by a Control Panel Receiver 100 compatibility with the Mier DA 610TO optional DA 611TO and optional DA 612TO Sensor transmitters Compatible with Mier Accessories detailed in this manual See Accessories Page EASY INSTALLATION IS OFTEN COMPLETED IN UNDER 30 MINUTES Plug In the Plug In or Place the Place the Sensor Control Panel ...

Страница 3: ... is to be mounted indoors 4 6 feet above ground level where 110 volts AC power is available To maximize transmitter reception the flexible antenna is to be at least 12 inches from any metal pipes power conduits breaker boxes etc Simply plug the Control Panel Receiver into a standard wall outlet where the signal from the Sensor Transmitter can reach it For extended mile range reception or when a Co...

Страница 4: ...ivity in the driveway See next two pages for directions Lightning strikes cause a large disturbance in the magnetic field so nearby strikes will cause an alarm It is also possible for electrical current variations in nearby power lines to cause an alarm The address codes for these Sensor Transmitters as well as the Control Panel Receivers are pre set at the factory However if a unique address code...

Страница 5: ... layer of silicone oil on the underside of the cover Failing to do either will result in moisture entering the enclosure The Sensor Transmitter can now be placed in position For maximum range the black box Transmitter portion of the DA 610TO DA 611TO or DA 612TO should be placed 3 to 4 feet above ground on a post tree etc The front of the Transmitter Box should also face the Control Panel Receiver...

Страница 6: ...an one Zone is to be monitored place jumpers on the Zone Pins on the electrical board in the black box to active them AND pull the jumper off of the JP3 Jumper Pin inside the white DA 700 or DA 100 Control Panel The Drive Alert will give a different Chime tone for each Zone monitored This photo of the Transmitter board inside the black box shows where to place the batteries turn it On see the Vali...

Страница 7: ... STABLE AND MOTIONLESS Any movement of the sensor will cause an alarm Don t mount the Sensor on a tree post or gate that might move in the wind DO NOT mount the Sensor where it might be near underground or above ground power lines Power surges in the sensor area will cause false alarms DO NOT bury the Transmitter Box in the ground DO NOT install the Transmitter Box in an Aluminum Copper or Steel e...

Страница 8: ...d to the GND terminal will operate the Drive Alert Therefore the Control Panel Receiver can become portable the sensor is always portable so the unit can be used in a vehicle or at a remote site NOTE DO NOT PLUG THE UNIT INTO 110 VAC IF ALSO OPERATED ON BATTERY AS IT CAUSES FAILURE SIG ALA 5VDC GND 24DC NO NC C NO C Connecting Line of Sight Wireless Transmitter such as Mier s DA 606LK Light Kit Th...

Страница 9: ...10 Sensor HARD WIRED DRIVE ALERT ACCESSORIES DA 655 DA 500LKA DA 052V DA 505 DA 505W DA 050 The Hard Wired DA 655 Chime with Volume Control is our most popular accessory for the model DA 500 Drive Alert in Drive up Window or business applications The DA 500LKA is a set of Form C Dry Contacts that can be attached to the DA 700 or DA 500 Control Panels The DA 052V Whistle with Volume Control used wi...

Страница 10: ... is actually a self contained Control Panel Receiver on its own and receives a signal from up to 1000 feet from any of Mier s wireless Sensor Transmitters OR a DA REPEATER shown above and provides a pleasant tone as an alert It also includes volume control The DA 611TO and DA 612TO Sensor Transmitters increase transmission distance The Sensor s is are outside the Transmitter Box and attached to th...

Страница 11: ...rized by Mier Products Inc may void the user s authority to operate this equipment IC ID 5583ADA 066MP Cet appareil est conforme a des reglements d industrie Canada exempts de license standard RSS s Son fonctionnement est soumis aux deux conditions 1 Ce dispositif ne doit pas causer d interferences nuisibles 2 Cel appareil doit accepter toute interference recue y compris les interferences pouvant ...

Страница 12: ...Tech Support They will work with you and might recommend returning the system to Mier Products for diagnosis and repair Panel is quiet replace the accessory Check the sensor transmitter placement 50 min away from the street power phone lines Move sensor or reduce sensitivity Existing New Accessory Defective OK OK OK Still Not Fixed Existing New OK Check the batteries Power is ON TX_TEST is OFF SW1...

Страница 13: ...tallation instructions Drive Alert accessories and parts built by other OEMs including but not limited to chimes lamp modules light switches bells splice kits are covered under their respective OEM warranties This warranty constitutes the entire warranty with respect to Mier s Drive Alert Models and Accessories and IS IN LIEU OF ALL OTHERS EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OR MERCHANTABI...

Отзывы: