background image

4

Wireless Drive-Alert Sensor/Transmitter Installation Guide

Mier Products’ Wireless Drive-Alert Sensor/Transmitters 

detect changes in the magnetic field 

(movement of metal) within 14 feet in every direction, based on a sedan traveling 5mph.  Therefore, 
they will not false-alarm from animals, wind, rain, etc.  The Transmitter boards are epoxied and 
encased in a durable, weather-sealed, box for worry free weather and corrosion protection.  They 
are able to detect through standard building materials such as brick, stone, vinyl siding, etc. so in 
many drive-up window applications they may be installed inside the wall next to the drive. They are 
powered by two AA batteries, Lithium are recommended, and include circuitry to transmit a low-
battery condition to Mier’s Drive-Alert Control Panel/Receivers when batteries begin to run low.

The Sensor (aka: probe or wand) portion of any of these Sensor/Transmitters should be placed next 
to the drive or area to be monitored, and at least 50 feet from any road traffic to prevent false alarms 
(see next page).  The Sensor should be parallel to the drive.  

Any movement of the Sensor will cause 

an alarm for asset protection (ex. a tractor, a trailer, gas pump, etc).

  

The range from the Transmitter to the Control Panel/Receiver is 500 feet if placed on the ground, up 
to 1000 feet if mounted 2-4 foot high on a wood or concrete post (never metal posts), and up to 3/4-
mile if a DA-660 Reception Booster Antenna is used.  (

See the Long Range Options page to learn 

more about the booster antenna, adding repeaters, or adding additional control panels

)

If occasional false alarms occur, or you are not detecting some vehicles, you can try re-locating the 
Sensor, or you can reduce sensor sensitivity.  There is a small blue sensitivity pot on the electrical 
board.  Maximum sensitivity adjustment is clockwise and minimum is counter-clockwise (note 
arrow direction).  Reducing sensitivity would reduce detection of road traffic, but would also reduce 
the detection sensitivity in the driveway.  (S

ee next two pages for directions

)

Lightning strikes cause a large disturbance in the magnetic field, so nearby strikes will cause an 
alarm.  It is also possible for electrical current variations in nearby power lines to cause an alarm.

The address codes for these Sensor/Transmitters, as well as the Control Panel/Receivers are pre-set at 
the factory.  However, if a unique address code is needed (e.g. interference from a neighbor’s Mier 
wireless Drive-Alert) you can change the address codes making sure you do so in 

both the Sensor/

Transmitter AND the Control Panel/Receiver 

so they are different than factory spec, but still match 

one another.  (S

ee next page for directions

)

The Differences between Mier’s three Sensor/Transmitter Choices:

* DA-610TO Sensor/Transmitter

:  Both the Sensor and the Transmitter are contained in the same 

   NEMA 4X enclosure. (See photo at the top left) This unit is standard with complete systems.

The DA-611TO Remote-Sensor/Transmitter:

  The Sensor is outside the Transmitter Box, and 

   attached to the Transmitter by a 50’ cable (cable lengths up to 2500 feet are available).  This 
   allows the sensor probe to be buried under or next to the driveway or area to be monitored, and 
   the transmitter box to be hidden up to 50’ away or placed high above ground for a better range.  
   The sensor should be buried 6-12 inches below ground and the cable 3-6 inches below ground.  
   Mier HIGHLY RECOMMENDS burying the cable in 1/2-inch PVC pipe to protect it.  

Try the 

   Sensor and Transmitter locations above ground for a week, before burying the Sensor and cable.

The DA-612TO Dual Sensor/Transmitter:

  Like the DA-611TO, but with 2 external sensors.

DA-611TO

Detection-distance from the sensor for a standard-size modern sedan moving 5MPH

    

DA-610TO 

DA-611TO/DA-612TO

Maximum sensitivity 

 

14 feet   

17 feet

Factory set sensitivity 

 

13 feet   

16 feet

75% sensitivity   

 

11 feet   

14 feet

50% sensitivity   

   

9 feet   

12 feet

Minimum sensitivity 

 

7 feet   

10 feet

DA-611TO installation with the Sensor 
buried under the drive and the 
Transmitter hidden/mounted on a 
nearby tree.

DA-610TO

DA-612TO

DA-610TO installation with the Sensor/
Transmitter hidden under landscaping 
next to the driveway.

Содержание DA-600

Страница 1: ...ering monitored area s 2 A control panel up to 1000 feet away receives a signal from the sensor and triggers an alert inside the home or business booster antenna increases range to 3 4 mile 3 Add remote plug in chimes in the front room basement upstairs back yard by the pool or in other buildings 4 Add a Timer Control to turn on outdoor and in door lights to warn strangers or welcome friends 5 Act...

Страница 2: ...allations page Use of an unlimited number of Mier Wireless Transmitters by a Control Panel Receiver 100 compatibility with the Mier DA 610TO optional DA 611TO and optional DA 612TO Sensor transmitters Compatible with Mier Accessories detailed in this manual See Accessories Page EASY INSTALLATION IS OFTEN COMPLETED IN UNDER 30 MINUTES Plug In the Plug In or Place the Place the Sensor Control Panel ...

Страница 3: ... is to be mounted indoors 4 6 feet above ground level where 110 volts AC power is available To maximize transmitter reception the flexible antenna is to be at least 12 inches from any metal pipes power conduits breaker boxes etc Simply plug the Control Panel Receiver into a standard wall outlet where the signal from the Sensor Transmitter can reach it For extended mile range reception or when a Co...

Страница 4: ...ivity in the driveway See next two pages for directions Lightning strikes cause a large disturbance in the magnetic field so nearby strikes will cause an alarm It is also possible for electrical current variations in nearby power lines to cause an alarm The address codes for these Sensor Transmitters as well as the Control Panel Receivers are pre set at the factory However if a unique address code...

Страница 5: ... layer of silicone oil on the underside of the cover Failing to do either will result in moisture entering the enclosure The Sensor Transmitter can now be placed in position For maximum range the black box Transmitter portion of the DA 610TO DA 611TO or DA 612TO should be placed 3 to 4 feet above ground on a post tree etc The front of the Transmitter Box should also face the Control Panel Receiver...

Страница 6: ...an one Zone is to be monitored place jumpers on the Zone Pins on the electrical board in the black box to active them AND pull the jumper off of the JP3 Jumper Pin inside the white DA 700 or DA 100 Control Panel The Drive Alert will give a different Chime tone for each Zone monitored This photo of the Transmitter board inside the black box shows where to place the batteries turn it On see the Vali...

Страница 7: ... STABLE AND MOTIONLESS Any movement of the sensor will cause an alarm Don t mount the Sensor on a tree post or gate that might move in the wind DO NOT mount the Sensor where it might be near underground or above ground power lines Power surges in the sensor area will cause false alarms DO NOT bury the Transmitter Box in the ground DO NOT install the Transmitter Box in an Aluminum Copper or Steel e...

Страница 8: ...d to the GND terminal will operate the Drive Alert Therefore the Control Panel Receiver can become portable the sensor is always portable so the unit can be used in a vehicle or at a remote site NOTE DO NOT PLUG THE UNIT INTO 110 VAC IF ALSO OPERATED ON BATTERY AS IT CAUSES FAILURE SIG ALA 5VDC GND 24DC NO NC C NO C Connecting Line of Sight Wireless Transmitter such as Mier s DA 606LK Light Kit Th...

Страница 9: ...10 Sensor HARD WIRED DRIVE ALERT ACCESSORIES DA 655 DA 500LKA DA 052V DA 505 DA 505W DA 050 The Hard Wired DA 655 Chime with Volume Control is our most popular accessory for the model DA 500 Drive Alert in Drive up Window or business applications The DA 500LKA is a set of Form C Dry Contacts that can be attached to the DA 700 or DA 500 Control Panels The DA 052V Whistle with Volume Control used wi...

Страница 10: ... is actually a self contained Control Panel Receiver on its own and receives a signal from up to 1000 feet from any of Mier s wireless Sensor Transmitters OR a DA REPEATER shown above and provides a pleasant tone as an alert It also includes volume control The DA 611TO and DA 612TO Sensor Transmitters increase transmission distance The Sensor s is are outside the Transmitter Box and attached to th...

Страница 11: ...rized by Mier Products Inc may void the user s authority to operate this equipment IC ID 5583ADA 066MP Cet appareil est conforme a des reglements d industrie Canada exempts de license standard RSS s Son fonctionnement est soumis aux deux conditions 1 Ce dispositif ne doit pas causer d interferences nuisibles 2 Cel appareil doit accepter toute interference recue y compris les interferences pouvant ...

Страница 12: ...Tech Support They will work with you and might recommend returning the system to Mier Products for diagnosis and repair Panel is quiet replace the accessory Check the sensor transmitter placement 50 min away from the street power phone lines Move sensor or reduce sensitivity Existing New Accessory Defective OK OK OK Still Not Fixed Existing New OK Check the batteries Power is ON TX_TEST is OFF SW1...

Страница 13: ...tallation instructions Drive Alert accessories and parts built by other OEMs including but not limited to chimes lamp modules light switches bells splice kits are covered under their respective OEM warranties This warranty constitutes the entire warranty with respect to Mier s Drive Alert Models and Accessories and IS IN LIEU OF ALL OTHERS EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OR MERCHANTABI...

Отзывы: