background image

8

Wireless Drive-Alert Control Panel Terminals and Hooking Up Other Equipment

The terminal block, TB1, provides a convenient wire connection point for external device control and test points.  

NOTE:  All external devices must be rated at 24 VDC

The DA-600/DA-605 terminals on the bottom left of the Control Panel’s green PCB, with the “Alert” and “Power” LEDs to the right 

•  Valid XMSN-  

Valid Transmission LED (far left) is RED and indicates if a valid signal is received from the Sensor/Transmitter

•  LOW BATT - 

Low Battery LED is YELLOW and indicates if the batteries in the Sensor/Transmitter are running low

•  SIG -  

 

Received Signal Strength (e.g. 1-1.5VDC = No Signal; 1.6-2.5VDC = Signal

•  +5VDC -    

5 Volt DC Logic Power @ 25mA (max)

•  ALA -  

 

Alarm Signal (0-1vdc = No Alarm; 4-5 VDC = Alarm)

•  GND -  

 

Unit Ground

•  +24VDC -    

Power Supply for 24VDC @ 100 mA (.1 amp) maximum accessories

•  NO -  

 

Normally Open Relay Contact

•  NC -  

 

Normally Closed Relay Contact

•  C -   

 

Common Relay Contact

•  NO -  

 

Normally Open Relay Contact

•  C -   

 

Common Relay Contact

ALERT LED -    

Alert LED is RED and lights when the Sensor/Transmitter has detected an intrusion and is sending a signal

POWER LED -    

Power LED is GREEN and remains on when the Control Panel/Receiver is plugged in and receiving power

NOTE:  The Control Panel/Receiver will operate on 12 VDC.  An auto battery with the positive (+) connected to the +24 VDC 
terminal and negative (-) connected to the GND terminal will operate the Drive-Alert.  Therefore, the Control Panel/Receiver can 
become portable (the sensor is always portable) so the unit can be used in a vehicle or at a remote site.

***** NOTE:  DO NOT PLUG THE UNIT INTO 110 VAC IF ALSO OPERATED ON BATTERY AS IT CAUSES FAILURE *****

   SIG    ALA  +5VDC  GND 

+24DC

    NO      NC        C        NO       C

Connecting Line of Sight Wireless Transmitter

such as Mier’s DA-606LK Light Kit

The Black and Red Wires attach to the last two 
terminals (NO and C isolated contacts)

   SIG    ALA  +5VDC  GND 

+24DC

    NO      NC        C        NO       C

Maximum Current 
Limited to 1 Ampere

Connection using dry contacts and external power

* Maximum Voltage is 24V   
   DO NOT apply 120VAC

BELL

External Power

   SIG    ALA  +5VDC  GND 

+24DC

    NO      NC        C        NO       C

Connecting a DA-066MP Wireless Chime Transmitter to a

DA-600 Control Panel

DA-066MP Push-Button 
Wireless Chime Transmitter

Jumper

Black

White

Red

   SIG    ALA  +5VDC  GND 

+24DC

    NO      NC        C        NO       C

External 24VDC Bell with 
Whistle Switch ON or OFF

Capacitor
0.1 Microfarads 100 Volt (min)
Adding a capacitor extends the life 
of the relay.

NOTE:
Limit of two external bells

BELL

Connection using relay contacts switching internal power

Jumper

   SIG    ALA  +5VDC  GND 

+24DC

    NO      NC        C        NO       C

NOTE:  If using a 

DA-500 hard-wired system

, and the internal piezo whistle is not wanted, move the 

Whistle Switch to the OFF position and connect the jumper b24 and the C Terminal

1N4004 DIODE
Adding the diode extends the life of the relay.

RELAY

External Relay 

Hookup

24VDC

To AC operated CHIMES/ALARMS

Connection using relay contacts switching internal power

Jumper

Black  Red

Содержание DA-600

Страница 1: ...ering monitored area s 2 A control panel up to 1000 feet away receives a signal from the sensor and triggers an alert inside the home or business booster antenna increases range to 3 4 mile 3 Add remote plug in chimes in the front room basement upstairs back yard by the pool or in other buildings 4 Add a Timer Control to turn on outdoor and in door lights to warn strangers or welcome friends 5 Act...

Страница 2: ...allations page Use of an unlimited number of Mier Wireless Transmitters by a Control Panel Receiver 100 compatibility with the Mier DA 610TO optional DA 611TO and optional DA 612TO Sensor transmitters Compatible with Mier Accessories detailed in this manual See Accessories Page EASY INSTALLATION IS OFTEN COMPLETED IN UNDER 30 MINUTES Plug In the Plug In or Place the Place the Sensor Control Panel ...

Страница 3: ... is to be mounted indoors 4 6 feet above ground level where 110 volts AC power is available To maximize transmitter reception the flexible antenna is to be at least 12 inches from any metal pipes power conduits breaker boxes etc Simply plug the Control Panel Receiver into a standard wall outlet where the signal from the Sensor Transmitter can reach it For extended mile range reception or when a Co...

Страница 4: ...ivity in the driveway See next two pages for directions Lightning strikes cause a large disturbance in the magnetic field so nearby strikes will cause an alarm It is also possible for electrical current variations in nearby power lines to cause an alarm The address codes for these Sensor Transmitters as well as the Control Panel Receivers are pre set at the factory However if a unique address code...

Страница 5: ... layer of silicone oil on the underside of the cover Failing to do either will result in moisture entering the enclosure The Sensor Transmitter can now be placed in position For maximum range the black box Transmitter portion of the DA 610TO DA 611TO or DA 612TO should be placed 3 to 4 feet above ground on a post tree etc The front of the Transmitter Box should also face the Control Panel Receiver...

Страница 6: ...an one Zone is to be monitored place jumpers on the Zone Pins on the electrical board in the black box to active them AND pull the jumper off of the JP3 Jumper Pin inside the white DA 700 or DA 100 Control Panel The Drive Alert will give a different Chime tone for each Zone monitored This photo of the Transmitter board inside the black box shows where to place the batteries turn it On see the Vali...

Страница 7: ... STABLE AND MOTIONLESS Any movement of the sensor will cause an alarm Don t mount the Sensor on a tree post or gate that might move in the wind DO NOT mount the Sensor where it might be near underground or above ground power lines Power surges in the sensor area will cause false alarms DO NOT bury the Transmitter Box in the ground DO NOT install the Transmitter Box in an Aluminum Copper or Steel e...

Страница 8: ...d to the GND terminal will operate the Drive Alert Therefore the Control Panel Receiver can become portable the sensor is always portable so the unit can be used in a vehicle or at a remote site NOTE DO NOT PLUG THE UNIT INTO 110 VAC IF ALSO OPERATED ON BATTERY AS IT CAUSES FAILURE SIG ALA 5VDC GND 24DC NO NC C NO C Connecting Line of Sight Wireless Transmitter such as Mier s DA 606LK Light Kit Th...

Страница 9: ...10 Sensor HARD WIRED DRIVE ALERT ACCESSORIES DA 655 DA 500LKA DA 052V DA 505 DA 505W DA 050 The Hard Wired DA 655 Chime with Volume Control is our most popular accessory for the model DA 500 Drive Alert in Drive up Window or business applications The DA 500LKA is a set of Form C Dry Contacts that can be attached to the DA 700 or DA 500 Control Panels The DA 052V Whistle with Volume Control used wi...

Страница 10: ... is actually a self contained Control Panel Receiver on its own and receives a signal from up to 1000 feet from any of Mier s wireless Sensor Transmitters OR a DA REPEATER shown above and provides a pleasant tone as an alert It also includes volume control The DA 611TO and DA 612TO Sensor Transmitters increase transmission distance The Sensor s is are outside the Transmitter Box and attached to th...

Страница 11: ...rized by Mier Products Inc may void the user s authority to operate this equipment IC ID 5583ADA 066MP Cet appareil est conforme a des reglements d industrie Canada exempts de license standard RSS s Son fonctionnement est soumis aux deux conditions 1 Ce dispositif ne doit pas causer d interferences nuisibles 2 Cel appareil doit accepter toute interference recue y compris les interferences pouvant ...

Страница 12: ...Tech Support They will work with you and might recommend returning the system to Mier Products for diagnosis and repair Panel is quiet replace the accessory Check the sensor transmitter placement 50 min away from the street power phone lines Move sensor or reduce sensitivity Existing New Accessory Defective OK OK OK Still Not Fixed Existing New OK Check the batteries Power is ON TX_TEST is OFF SW1...

Страница 13: ...tallation instructions Drive Alert accessories and parts built by other OEMs including but not limited to chimes lamp modules light switches bells splice kits are covered under their respective OEM warranties This warranty constitutes the entire warranty with respect to Mier s Drive Alert Models and Accessories and IS IN LIEU OF ALL OTHERS EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OR MERCHANTABI...

Отзывы: