8
Wireless Drive-Alert Control Panel Terminals and Hooking Up Other Equipment
The terminal block, TB1, provides a convenient wire connection point for external device control and test points.
NOTE: All external devices must be rated at 24 VDC
The DA-600/DA-605 terminals on the bottom left of the Control Panel’s green PCB, with the “Alert” and “Power” LEDs to the right
• Valid XMSN-
Valid Transmission LED (far left) is RED and indicates if a valid signal is received from the Sensor/Transmitter
• LOW BATT -
Low Battery LED is YELLOW and indicates if the batteries in the Sensor/Transmitter are running low
• SIG -
Received Signal Strength (e.g. 1-1.5VDC = No Signal; 1.6-2.5VDC = Signal
• +5VDC -
5 Volt DC Logic Power @ 25mA (max)
• ALA -
Alarm Signal (0-1vdc = No Alarm; 4-5 VDC = Alarm)
• GND -
Unit Ground
• +24VDC -
Power Supply for 24VDC @ 100 mA (.1 amp) maximum accessories
• NO -
Normally Open Relay Contact
• NC -
Normally Closed Relay Contact
• C -
Common Relay Contact
• NO -
Normally Open Relay Contact
• C -
Common Relay Contact
ALERT LED -
Alert LED is RED and lights when the Sensor/Transmitter has detected an intrusion and is sending a signal
POWER LED -
Power LED is GREEN and remains on when the Control Panel/Receiver is plugged in and receiving power
NOTE: The Control Panel/Receiver will operate on 12 VDC. An auto battery with the positive (+) connected to the +24 VDC
terminal and negative (-) connected to the GND terminal will operate the Drive-Alert. Therefore, the Control Panel/Receiver can
become portable (the sensor is always portable) so the unit can be used in a vehicle or at a remote site.
***** NOTE: DO NOT PLUG THE UNIT INTO 110 VAC IF ALSO OPERATED ON BATTERY AS IT CAUSES FAILURE *****
SIG ALA +5VDC GND
+24DC
NO NC C NO C
Connecting Line of Sight Wireless Transmitter
such as Mier’s DA-606LK Light Kit
The Black and Red Wires attach to the last two
terminals (NO and C isolated contacts)
SIG ALA +5VDC GND
+24DC
NO NC C NO C
Maximum Current
Limited to 1 Ampere
Connection using dry contacts and external power
* Maximum Voltage is 24V
DO NOT apply 120VAC
BELL
External Power
SIG ALA +5VDC GND
+24DC
NO NC C NO C
Connecting a DA-066MP Wireless Chime Transmitter to a
DA-600 Control Panel
DA-066MP Push-Button
Wireless Chime Transmitter
Jumper
Black
White
Red
SIG ALA +5VDC GND
+24DC
NO NC C NO C
External 24VDC Bell with
Whistle Switch ON or OFF
Capacitor
0.1 Microfarads 100 Volt (min)
Adding a capacitor extends the life
of the relay.
NOTE:
Limit of two external bells
BELL
Connection using relay contacts switching internal power
Jumper
SIG ALA +5VDC GND
+24DC
NO NC C NO C
NOTE: If using a
DA-500 hard-wired system
, and the internal piezo whistle is not wanted, move the
Whistle Switch to the OFF position and connect the jumper b24 and the C Terminal
1N4004 DIODE
Adding the diode extends the life of the relay.
RELAY
External Relay
Hookup
24VDC
To AC operated CHIMES/ALARMS
Connection using relay contacts switching internal power
Jumper
Black Red