Technical Information
T300 Series Clothes Dryer (Condenser)
6.2
Checking Residual Moisture Stages
6.2.1
T 368 C, T 369 C with EF 102 / EF 202 (Tester, Part no. A5300)
1. Open front door panel or remove the appliance lid - – Refer to
Section 5.2 or 5.1.1.
2. Connect the 7-pole plug of the test module to the 7-pole socket
(service connection) on the electronic unit.
3. Connect the multimeter to the test module by plugging into the
sockets near the rotary knob.
4. Carry out tests according to the test chart.
Test Module Setting: 1
Program
Setting
Selector
Position
Current
EF 202
EF 202 from
Part no.
1752331
Extra Dry
2
2 µA
-
10
2 µA
-
Normal 11-14
0.018
mA -
Hand Iron (1 drop)
18
0.44 mA
-
Hand Iron (2
drops)
21-22 1.50
mA
-
Machine Iron
26-29
3.2 mA
-
32-35
2 µA
-
Normal
37-40
0.12 mA
0.40 mA
Table 6-2:
Test Module Setting 1
50