Technical Information
T300 Series Clothes Dryer (Condenser)
5.18
Fill Ring Seal
5.18.1
Replacement
Figure 5-27:
Fill Ring Seal Replacement
1. Open the front panel – Refer to Section 5.2.1.
Note:
If the fill ring and duct are combined to form one piece, remove the
screws indicated in Figure 5-11 – Fan Unit with Drum Drive Motor
Removal, then change the seal.
2. Remove the vent duct (refer to Section 5.6.1 – Fan Unit Removal -
Machine Nos. without Prefix, Steps 3-5).
3. Remove the 8 screws (refer to Figure 5-27 – Fill Ring Seal
Replacement, Item 1) and remove the fill ring.
4. Replace the seal.
46