Technical Information
T300 Series Clothes Dryer (Condenser)
6.4 Leaks
6.4.1
At the Front Door of the Condenser Box
Possible Cause
Bad join in seal. Seal too soft or thin resulting in insufficient sealing
pressure.
Fault Rectified
From Machine no. 6867167.
Remedy
Fit new seal, Part no. 2396050.
6.4.2
At the Rear of the Condenser Box
Possible Cause
Poor seal between the rear of the heat exchanger and the condenser box.
Fault Rectified
From Machine no. 6867167.
Remedy
Fit new seal, Part no. 1290482.
Note:
The seal must be fitted so as to ensure that the seal lips face towards the
heat exchanger.
6.4.3
Connecting Hose (Condensate Pump)
Possible Cause
Unprotected hose worn through by abrasive action from the drum as its
wire retainer is missing.
Fault Rectified
From Machine no. 7048138.
Remedy
Replace the hose and fix it with a retaining clip, Part no. 1418830, to the
condenser box – fan connection hose.
58