Installation
*
I
N
S
T
A
L
L
A
T
I
O
N
*
83
Electrical connection
This description applies to tumble dry-
ers both with and without a mains
plug.
The following applies to tumble dryers
with a mains plug:
– This tumble dryer is supplied with a
mains cable and plug ready for con-
nection.
– The electrical socket must be easily
accessible so that the tumble dryer
can be disconnected from the electri-
city supply.
Damage caused by incorrect
supply voltage.
The data plate indicates the nominal
power consumption and the appro-
priate fuse rating.
Compare the specifications on the
data plate with those of the mains
electricity supply and make sure that
they match.
The tumble dryer may only be connec-
ted to a permanent electrical system
that conforms to the national and local
codes and regulations.
The tumble dryer should never be con-
nected by an extension cable, e.g.
power strips, to avoid the risk of fire.
If the machine is hard wired, a dual cir-
cuit breaker must be provided on-site.
When switched off there must be an all-
pole contact gap of at least 3 mm in the
isolator switch (including miniature cir-
cuit breaker, switch, fuses and relays
according to IEC/EN 60947). This con-
nection process must be performed by
a qualified electrician.
The plug connector or isolator switch
should be easily accessible at all times.
Risk of electric shock from mains
voltage.
If the tumble dryer is disconnected
from the mains, protective measures
must be taken to ensure that the
point of disconnection cannot acci-
dentally be switched on again.
Make sure the isolator is lockable or
the point of disconnection is mon-
itored at all times.
New connections, modifications to the
system, or servicing of the earthing
conductor, including determining the
correct fuse amperage, must be carried
out by a qualified electrician, as they
are familiar with the pertinent regula-
tions and the specific requirements of
the electric utility company.
The tumble dryer must not be con-
nected to devices such as timers
which would switch it off automatic-
ally.
Single phase AC 230 V – country vari-
ant 230V 25A
This device is intended for connection
to a power supply system where the
maximum value of external phase neut-
ral loop impedance Zmax of 0.38 Ohms
at the point of distributor supply con-
nection is not exceeded.
The user has to ensure that this device
is connected only to a power supply
system which fulfils the requirement
above. If in doubt, please ask your elec-
trical distributor for actual impedance
value.