Installation
*INSTALLATION*
70
Safety distance when installing the appliance near a wall with additional
niche cladding
A minimum safety distance must be maintained between the worktop cut-out and
any niche cladding to protect it from heat damage.
If the niche cladding is made from a combustible material (e.g. wood) a minimum
safety distance
of 50 mm must be maintained between the cut-out and the
cladding.
If the niche cladding is made from a non-combustible material (e.g. metal, natural
stone, ceramic tiles) the minimum safety distance
between the cut-out and the
cladding will be 50 mm less the thickness of the cladding.
Example: 15 mm niche cladding
50 mm - 15 mm = minimum safety distance of 35 mm
Flush-fitted hobs
Hob with frame or bevelled edge
a
Masonry
b
Niche cladding dimension x = thickness of the niche cladding material
c
Worktop
d
Worktop cut-out
e
Minimum distance to
combustible
materials 50 mm
non-combustible
materials 50 mm - dimension x
Содержание KMDA 7476 FL
Страница 2: ......
Страница 73: ...Installation INSTALLATION 73 Installation examples Recirculation mode Extraction mode ...
Страница 77: ...Installation INSTALLATION 77 Extraction to the rear standard Extraction to the right Extraction to the left ...
Страница 79: ...Installation INSTALLATION 79 Extraction to the rear standard Extraction to the right Extraction to the left ...
Страница 82: ...Installation INSTALLATION 82 Extraction to the rear standard Extraction to the right Extraction to the left ...
Страница 84: ...Installation INSTALLATION 84 Extraction to the rear standard Extraction to the right Extraction to the left ...
Страница 97: ......
Страница 98: ......
Страница 100: ...M Nr 11 843 250 00 en SA KMDA 7476 FR KMDA 7476 FL ...