Problem solving guide
63
Issue
Cause and remedy
The food in the pan
does not heat up when
the Auto heat-up
function is switched on.
A large amount of food is being heated up.
Start cooking at the highest power level and then
turn down to a lower one manually later on.
The pan is not conducting heat properly.
Use a different pot or pan which conducts heat
properly.
An operating noise can
be heard after the
appliance has been
switched off.
The cooling fan runs until the hob has cooled down
and then switches off automatically.
is flashing
alternately with
in the
timer display and the
buzzer is sounding.
The hob is incorrectly connected.
Disconnect the hob from the mains electricity
supply.
Contact your Miele dealer. The hob must be
connected to the mains according to the wiring
diagram.
“E” and a number,
e.g. E-0, is flashing
alternately with a 3-digit
number in the timer
display.
Numbers
–
The fan is blocked or defective.
Make sure it has not been blocked by an object.
Remove the obstruction.
If this fault code continues to appear in the
display, contact your Miele dealer.
Other numbers
Fault in a zone
Disconnect the power supply to the hob for
approx. 1 minute.
If the problem persists after power has been
restored, please contact your Miele dealer.
Liquid has got into the
cooker hood.
Due to boiling over or spillage, liquid has made its
way through the extraction grille into the cooker
hood.
The base of the grease filter can hold approx. 250 ml
of liquid. The drip tray underneath the housing can
hold a further 250 ml of liquid.
Switch the cooker hood off.
Clean the grease filter, the drip tray and the inside
of the housing (see “Cleaning and care”).
Содержание KMDA 7476 FL
Страница 2: ......
Страница 73: ...Installation INSTALLATION 73 Installation examples Recirculation mode Extraction mode ...
Страница 77: ...Installation INSTALLATION 77 Extraction to the rear standard Extraction to the right Extraction to the left ...
Страница 79: ...Installation INSTALLATION 79 Extraction to the rear standard Extraction to the right Extraction to the left ...
Страница 82: ...Installation INSTALLATION 82 Extraction to the rear standard Extraction to the right Extraction to the left ...
Страница 84: ...Installation INSTALLATION 84 Extraction to the rear standard Extraction to the right Extraction to the left ...
Страница 97: ......
Страница 98: ......
Страница 100: ...M Nr 11 843 250 00 en SA KMDA 7476 FR KMDA 7476 FL ...