Conversion to another type of gas
*INSTALLATION*
57
Risk of explosion due to an
incorrect conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an authorised and registered gas
installer in strict accordance with
current local and national safety and
building regulations. The installer is
responsible for ensuring that the
appliance functions correctly when
installed. Disconnect the cooktop
from the electricity supply and turn
off the gas supply.
Jet table
The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Main jet
Small jet
NG
Auxiliary
burner
0.90
0.52
Semi-rapid
burner
1.10
0.52
Rapid burner
1.43
0.60
Wok burner
2x 1.27 / 0.90
0.44
ULPG
Auxiliary
burner
0.52
0.23
Semi-rapid
burner
0.66
0.36
Rapid burner
0.81
0.44
Wok burner
2x 0.70 / 0.46
0.25
Changing the jets
Disconnect the cooktop from the
electricity supply and turn off the gas
supply.
When converting to another type of
gas, both the main
and
small jets
need to be changed.
Changing the main jets
Auxiliary, semi-rapid and rapid
burners
Remove the pan support, burner
cap
and burner head
.
Using an M7 socket spanner,
unscrew the main jet
.
Fit the correct jets securely (see jet
table).
Secure the jets against inadvertent
loosening with sealing wax.