Electrical connection
99
Danger of injury!
Installation, repairs and other work
by unqualified persons could be
dangerous. Miele cannot be held
liable for unauthorised work.
Ensure power is not supplied to the
appliance until after installation or
repair work has been carried out.
All electrical work must be
undertaken by a suitably qualified
and competent person in strict
accordance with current national and
local safety and building code
regulations.
Connection of this appliance must
comply with national and local safety
regulations.
Connection to a switched socket
is
recommended as this provides easier
access in the case of a service call.
For extra safety, it is advisable to
protect the appliance with a suitable
residual current device (RCD) with a trip
current of 30 mA.
If the switch is not accessible after
installation an additional means of
disconnection must be provided for all
poles. The means of disconnection
must be incorporated in the fixed wiring
in accordance with the wiring rules.
When switched off there must be an all-
pole contact gap of 3 mm in the isolator
switch (including switch, fuses and
relays).
Connection data
AC 230V, 50 Hz
The voltage and rated load are given on
the data plate situated at the front of
the oven frame visible with the oven
door open. Please ensure the
connection data matches the
household supply.
When contacting Miele, please quote
the following:
– Model number
– Serial number
– Connection data (voltage/frequency/
maximum rated load).
If the mains connection cable is
damaged, it must be replaced by a
suitably qualified electrician with a
specialist connection cable of type
H 05 VV-F, available from Miele, in
order to avoid a hazard.
WARNING - THIS APPLIANCE
MUST BE EARTHED