DOS 3 (neutralizer)
Setting the neutralizer dosage
Set dosage concentration according to the neutralizer manufacturer's
recommendations.
Step
Display / Result
^
Press the "Drying"
0
button until E02
appears in the display.
E02
^
Turn the program selector to "Intensive".
The programmed dosage
concentration appears in the
display, e.g.,
0.10
= 0.10 %
^
Press and hold the "Display"
ß
button
until the required value appears in the
display, e.g., 0.2.
0.20
The dosage concentration is
now set.
Dosage concentration setting:
Priming the dosage system
The dosage system does not need to be primed (cleared of air) unless:
– the dosage concentration is being set for the first time,
– the neutralizer container was inadvertently completely emptied .
Step
Display / Result
^
Press the "Drying"
0
button until E02
appears in the display.
E02
^
Turn the program selector to "Universal".
d§3
^
Press the "Display"
ß
button.
The dosage system will be primed
automatically. Priming is complete
when
0
appears in the display.
^
Exit the programming mode.
Start "Rinse" program.
This will rinse away any agents that
entered the wash cabinet during
priming.
Programming functions