Setting the time and date
The date and time are set in the serial interface (optional accessory). This
information appears in the print log.
The date and time can be changed, e.g., from daylight saving to standard time.
Use the program selector to activate the desired time and date:
1 o'clock position: Calendar day
01
-
31
2 o'clock position: Month
01
-
12
3 o'clock position: Year
00
-
99
= 2000 - 2099
4 o'clock position: Hours
00
-
23
5 o'clock position: Minutes
00
-
59
When level
E34
is selected without an activated serial interface, a "
-"
appears in
the display for all program selector positions.
Step
Display / Result
^
Press and hold the "Drying"
0
button until E34
appears in the display.
E34
Wait approximately 30 sec before the next step.
The control unit retrieves the
currently stored values.
^
Switch the program selector to the position for the
value you wish to change, e.g., to the 4 o'clock
position to set the hour.
10
^
Press and hold the "Display"
ß
button until the
required value appears in the display, e.g., 1 x.
11
, the hour is changed.
Wait approximately 30 sec before turning off the
machine.
The updated values are
transmitted to the serial
interface.
Once the values are saved and you have exited the programming mode, the
updated values are transmitted to the interface. Therefore wait about 30
seconds before switching off the machine.
Programming functions
46