Installation
*INSTALLATION*
37
Place a spirit level across the
installation aids
on the appliance
door to check the refrigeration
appliance’s alignment.
Unscrew the adjustable feet
and
on both sides at least until the
marking on the plinth has reached the
specified distance of 32 mm on the
spacer
. The standard dimension of
32 mm relates to a niche height of
2134 mm.
It is important to adjust the feet to a
height of at least 32 mm so that the
ventilation of the refrigeration
appliance via the plinth functions
correctly.
Risk of damage if the feet are
adjusted too much.
The rear adjustable feet can be
damaged.
Unscrew the feet
only until
the
marking on the plinth is aligned to a
maximum of 62 mm (max. niche
height of 2164 mm).
Check the alignment of the
refrigeration appliance again using
the installation aids
and the spirit
level.
Securing the refrigeration appliance
in the building-in niche
Screw the lugs for the fixing plate
into the cabinets/units above the
appliance.
Содержание F 2411 Vi
Страница 22: ...Installation INSTALLATION 22 30 mm 22 mm 262 mm 102 mm 102 mm 85 mm Side view ...
Страница 116: ......
Страница 117: ......
Страница 118: ......
Страница 120: ...M Nr 11 633 570 00 en AE SA F 2411 Vi F 2801 Vi F 2811 Vi F 2901 Vi F 2911 Vi ...