Technical Information
CVA4070 / CVA4075 Coffee Systems
1 Temperature limiter
2 Temperature sensor
3 Temperature fuse
Figure 5-33:
CVA4070 Temperature
10. Remove the temperature limiter, temperature sensor and temperature
fuse (Figure 5-33, Items 1 – 3).
11. Pull the connectors off the flow-thru heater.
Warning!
To prevent malfunctions in the water system (for example clogging of the
valves), never use grease, oil or other lubricants when assembling the
water supplying components.
72