Technical Information
CVA4070 / CVA4075 Coffee Systems
1 Flow-thru heater steam
2 Flow-thru heater coffee/hot water
Figure 5-31:
CVA4070 Flow-thru Heater Steam
1 Retaining screws flow-thru heater
Figure 5-32:
CVA4070 Flow-thru Heater Steam
7. Pull out the spring clips at the connection (Figure 32).
8. Remove the flow-thru heater mounting screws (Figure 32, Item 1).
9. S/B Remove center screw.
10. Remove the flow-thru heater.
71