Installation
47
Drainage
DN 70 drain valve
AV
on the machine, DN 70 sleeve on-site.
Throughflow rate 200 l/min.
If the slope for drainage is extremely steep, the piping must be vented
to prevent formation of a vacuum in the machine's drain system.
Foam and vapour venting kit
BWS
If excessive suds form, foam may escape from the vapour vent. To
remove the foam, an optional vapour venting kit (BWS) can be used.
Electrical connection
The electrical connection must only be carried out by a suitably
qualified electrician in accordance with local and national regulations.
Useful tip:
Open the machine lid. The connection terminals are
located on the machine support.
When installing a residual current device (RCD), it must be
Type B
.
The electrical components of this machine comply with
DIN EN 60335-1, DIN EN 50571.
See data plate for voltage data.
If the machine is hard wired, an all-pole isolator must be installed.
Switches with a minimum contact gap greater than 3 mm are suitable
isolators. These include circuit breakers, fuses, and contactors
(VDE 0660).
The plug connector or isolator switch should be easily accessible at
all times.
If the appliance is disconnected from the electricity supply, the
isolator must be lockable or the point of disconnection must be
monitored at all times.
Observe the enclosed wiring diagram.
Содержание 51514001AUS
Страница 63: ......