Chapter 1: Introduction & Overview

Safet

y Reminder

For safe, efficient, and accurate charging and testing, review 

the safety and operating instructions in this manual before 

using the analyzer. In addition, follow all manufacturer 

instructions and BCI (Battery Council International) safety 

recommendations.

Safety Precautions

Inspect the battery for damages and check the electrolyte 

level. If the electrolyte level is too low, replenish it and 

fully charge the battery. Always use the necessary safety 

precautions when working with batteries to prevent severe 

injury or death. Follow all manufacturers’ instructions and 

BCI (Battery Council International) safety recommendations, 

which include the following precautions:

Risk of explosive gases. 

Never smoke or allow a spark or 

flame in the vicinity of a battery.

Batteries can produce a highly explosive mix 

of hydrogen gas and oxygen, even when the 

battery is not in operation. Always work in a 

well-ventilated area..

Wash hands after handling.

REQUIRED BY CALIFORNIA PROP. 65: Battery posts, 

terminals, and related accessories contain lead and lead 

compounds, chemicals known to the state of California 

to cause cancer and birth defects or other reproductive 

harm.

 

9

Battery acid is highly corrosive. If acid enters your eyes, im-

mediately flush them thoroughly with cold running water 

for at least 15 minutes and seek medical attention. If bat-

tery acid gets on your skin or clothing, wash immediately 

with a mixture of water and baking soda.

 

9

Always wear proper safety glasses or face shield when 

working with or around batteries.

 

9

Keep hair, hands, and clothing as well as the analyzer 

cords and cables away from moving engine parts.

 

9

Remove any jewelry or watches before you start servicing 

the battery.

 

9

Use caution when working with metallic tools to prevent 

sparks or short circuits.

 

9

Never lean over a battery when testing, charging, or jump 

starting.

 

9

Never charge a frozen battery. Gases may form, cracking 

the case, and spray out battery acid.

Manual Conventions

This manual uses these symbols and typographical conventions:

Symbol

Description

The safety symbol indicates instructions for 

avoiding hazardous conditions and personal 

injury.
The safety symbol with the words 

CAUTION

WARNING, or DANGER

 indicates instructions 

for avoiding hazardous conditions and 

personal injury.
The wrench symbol indicates procedural notes 

and helpful information.



These symbols indicate which arrow keys on 

the keypad to press for a given function.

Bold Letters

The text for screen options are in 

Bold

 letters.

Top View

  

 

Power Connection

 

Connector: Charge Cables

 

DC Output Circuit Breaker

 

USB Port

 

Serial Connector  

  

(r LIN/CAN)

 

Charge Cable Quick  

 

Connector Locking Posts

Chapter 1: Introduction & Overview

Содержание MCC-070

Страница 1: ...INSTRUCTION MANUAL MCC 070 EU Controlled Charger JAN 2019 167 000651EN B...

Страница 2: ...MCC 070 Controlled Charger Midtronics BV Hoofdveste 6 8 3992 DG Houten www midtronics com 2...

Страница 3: ...1 Connections 11 Carrying Handle Optional 11 Stabilizing Base 11 Locking Power Cord 11 Charging Cables 11 Menu Layout 12 Main Menu 12 Settings Menu 13 Settings Sub Menus 13 Tool 13 Shop Settings 13 Ne...

Страница 4: ...MCC 070 Controlled Charger Midtronics BV Hoofdveste 6 8 3992 DG Houten www midtronics com 4...

Страница 5: ...arp blow been dropped or otherwise damaged in any way take it to a qualified service center 1 6 Do not disassemble charger take it to a qualified service center when repair is required Incorrect reass...

Страница 6: ...set at the correct voltage If the charger has an adjustable charge rate charge the battery initially at lowest rate If the charger has only one voltage verify that the battery voltage matches the vol...

Страница 7: ...the battery being charged gases from the battery will corrode and damage the charger 5 4 Never allow battery acid to drip on the charger when tak ing gravity readings or filling a flooded cell batter...

Страница 8: ...ive and can damage the clamps over time Before connecting the clamps ensure accurate test readings and protect the clamps by cleaning the bat tery case and terminals using a wire brush and a mixture o...

Страница 9: ...15 5 VDC 70A maximum Humidity 15 to 85 R H non condensing Dimensions without handle or base Height 4 80 in 12 19 cm Width 13 1 in 33 27 cm Length 12 0 in 30 48 cm Weight 16 75 lbs 7 6 kg Temperature O...

Страница 10: ...s highly corrosive If acid enters your eyes im mediately flush them thoroughly with cold running water for at least 15 minutes and seek medical attention If bat tery acid gets on your skin or clothing...

Страница 11: ...o the back of the charger using the four 4 included Phillips head screw and the appropriate threaded holes Stabilizing Base Secure the stabilizing base to the back of the charger using the two 2 inclu...

Страница 12: ...se Main Menu The Main Menu is the starting point for all tools and utilities which are depicted as icons Some icons lead directly to the function they represent while others are menu icons that lead t...

Страница 13: ...the Date Format the actual Date Time Format and the actual Time Power Supply Set the default maximum and minimum voltages used when the tool is in Power Supply mode Version Check the software version...

Страница 14: ...mp to the positive terminal and the black clamp to the negative terminal An alert is displayed if the clamps are reversed on the battery terminals To make sure both sides of the clamps are gripping th...

Страница 15: ...Continue 7 While this screen is displayed the charger is actually con tinuing to charge the battery in the background filling it to maximum capacity The charger will continue to do this until the bat...

Страница 16: ...displayed the charger is actually con tinuing to charge the battery in the background filling it to maximum capacity The charger will continue to do this until the battery s acceptance of the charge i...

Страница 17: ...l Ah Replaced Amp hours replaced in the battery Chemistry Battery chemistry selected by the technician Time Elapsed The elapsed time for the total charging session Possible Battery Decisions Battery D...

Страница 18: ...MCC 070 Controlled Charger Midtronics BV Hoofdveste 6 8 3992 DG Houten www midtronics com 18 Chapter 2 Charging...

Страница 19: ...to enter the month day and year Tap Set to save the date or Cancel to exit without saving Sep 17 2015 Oct 18 2016 Nov 19 2017 CANCEL SE T Time Format Select AM PM or 24 hour Time Tap or to enter the...

Страница 20: ...anually configure the charger IP Setup and set up a CVG3 Automatic Automatically scan for detectableWiFi networks and select a network from the displayed list for which to connect The selected network...

Страница 21: ...uten www midtronics com 21 Chapter 3 Settings Records Records Display either individual test records or a list of records including VIN Year Make and Model information Devices Devices Manage the Midtr...

Страница 22: ...MCC 070 Controlled Charger Midtronics BV Hoofdveste 6 8 3992 DG Houten www midtronics com 22 Chapter 3 Settings...

Страница 23: ...MCC 070 Controlled Charger Midtronics BV Hoofdveste 6 8 3992 DG Houten www midtronics com 23 Chapter 3 Settings...

Страница 24: ...nc and is protected by one or more U S and foreign patents For specific patent information contact Midtronics Inc at 1 630 323 2800 Midtronics products are warranted to be free of defects in materials...

Отзывы: