Chapter 1: Before You Begin

Starting the tester for the fi rst time

When the tester is fi rst used the operator is asked to enter a 

couple of items such as language, date and time. Changes 

can be made afterwards by going in to the Utility Menu and 

selecting CONFIG TESTER.

Safety

Because of the possibility of personal injury, always use 

extreme caution when working with batteries. Follow 

all manufacturers’ instructions and BCI (Battery Council 

International) safety recommendations.

General Precautions

 

Battery acid is highly corrosive. If acid enters your 

eyes, immediately fl ush them thoroughly with run-

ning cold water for at least 15 minutes and seek 

medical attention. If battery acid gets on your skin or 

clothing, wash immediately with water and baking 
soda.

 

Always wear proper safety glasses or face shield 

when working with or around batteries. 

 

Keep hair, hands, and clothing as well as the analyzer 
cords and cables away from moving engine parts.

 

Remove any jewelry or watches before you start 
servicing the battery. 

 

Use caution when working with metallic tools to 

prevent sparks or short circuits.

 

Never lean over a battery when testing, charging or 

jump starting it.

Risk of explosive gases.

Never smoke or allow a spark or 

fl ame in the vicinity of a battery.

Batteries can produce a highly explosive mix 

of hydrogen gas and oxygen, even when the 

battery is not in operation. Always work in a 

well-ventilated area.

Wash hands after handling.

REQUIRED BY CALIFORNIA PROP. 65: Battery posts, terminals, 

and related accessories contain lead and lead compounds, 

chemicals known to the state of California to cause cancer and 

birth defects or other reproductive harm.

The tester is manufactured in line with the latest state of the 

art and according to recognised safety standards. If used 

incorrectly or misused, however, it can cause

- injury or death to the user or a third party,

- damage to the tester and other material assets belonging 

to the operator,

- ineffi  cient operation of the tester.

All persons involved in commissioning, operating, maintaining 

and servicing the tester must

- be suitably qualifi ed,

- have knowledge of and experience in dealing with 

testers and batteries and

- read and follow these operating instructions carefully.

Chapter 1: Before You Begin

Conventions Used in This Manual

To help you learn how to use your analyzer, the manual uses these symbols and typographical conventions: 

Convention

Description

!

The safety symbol followed by the word

 WARNING or CAUTION indicates 

instructions

 for avoiding 

hazardous conditions and personal injury.

CAUTION

The word 

CAUTION

 indicates instructions for avoiding equipment damage.

The wrench symbol indicates procedural notes and helpful information.

UP ARROW

The text for keypad buttons and soft-key functions are in bold capital letters.

CAPITAL LETTERS

The text for screen options are in regular capital letters.

Содержание MAR-800P

Страница 1: ...INSTRUCTION MANUAL Marine Battery Electrical Diagnostic Analyzer MAR 800P...

Страница 2: ...This page intentionally left blank...

Страница 3: ...d 12 Surface Charge 12 Deep Scan Test 12 Battery Test Results 12 New Battery Test Result 13 Pair Test Result 13 Pack Test Result 13 Chapter 5 System Test 14 Battery Test 14 Starter Test 14 Starter Sys...

Страница 4: ...losive mix of hydrogen gas and oxygen even when the battery is not in operation Always work in a well ventilated area Wash hands after handling REQUIRED BY CALIFORNIA PROP 65 Battery posts terminals a...

Страница 5: ...cable see the next page for detail Spring loaded data card slot for test data storage and software upgrades Infrared temperature sensor with a range of 28 C to 93 C 20 F to 200 F Data transmitter sen...

Страница 6: ...e of information requested The four types of entry methods are described below Typically the soft key below the right half of the screen confirms your choice although the word above it may vary In a s...

Страница 7: ...nd off The analyzer also turns on automatically when you connect its test leads to a battery Title Bar The title bar shows you the name of the current menu test tool utility or function Selection Area...

Страница 8: ...st counter and more UTILITY MENU includes functionality to setup the tester Print View Menu Icon Description BATTERY RESULTS displays the results of the last battery test performed and the totals by b...

Страница 9: ...test make sure all vessel accessory loads are off If systems in the vessel are still active it might lead to a SYSTEM NOISE message the tester will automatically continue to test the battery until the...

Страница 10: ...E AUXILIARY Battery Standards Rating System Description Range MCA Marine Cranking Amps 100 to 2000 EN A European Norm 100 to 2000 CCA Cold Cranking Amps specified by SAE The amount of current a batter...

Страница 11: ...2000 CCA Cold Cranking Amps specified by SAE The amount of current a battery can provide at 0 F 17 8 C 100 to 2000 JIS Japanese Industrial Standard shown on a battery as a combination of numbers and...

Страница 12: ...hen to turn the head lights on and off IN VESSEL 2 The tester will resume testing after it detects that the sur face charge is removed Deep Scan Test In some cases the tester may need to further analy...

Страница 13: ...frost the battery and retest 24 VOLT SYSTEM 24 volt system detected Connect to 12V battery instead of the system LOW VOLT REPLACE Battery voltage is too low Pair Test Result Decision Recommended Actio...

Страница 14: ...cases the tester may not detect the vessel s starting profile It will display the soft key options STARTED and NO START If you select STARTED the analyzer skips to the Alternator Test If you select NO...

Страница 15: ...Do not use cyclical loads such as air condi tioning 4 TESTING ALTERNATOR WITH LOADS ON The analyzer will determine if the charging system is able to provide suf ficient current for the demands of the...

Страница 16: ...ns from the alternator to the battery If the connection is loose or heavily corroded clean or replace the cable and retest HIGH VOLTAGE The voltage output from the alternator to the battery exceeds th...

Страница 17: ...the UP or DOWN ARROW key or use the LEFT or RIGHT ARROW key to move up or down four part numbers at a time Press the NEXT soft key to continue 3 Press an UP or DOWN ARROW key to select the BATTERY RAT...

Страница 18: ...est Chapter 7 Drain Test With the drain test you can check the amount of current that is lost as a result of leakage 1 Measure the drain current with the external amp meter 2 Enter the drain current a...

Страница 19: ...7 IEC 4 JIS 8 NONE Press the NEXT soft key to continue The BACK soft key returns you to the previous screen 4 Select the battery rating Press the UP and DOWN ARROW keys to select the rating In case o...

Страница 20: ...e UP DOWN LEFT and RIGHT ARROW keys The Print View Menu enables you to view and print the results of the last test performed Print View also allows you to view and print test decision totals To return...

Страница 21: ...fo using the UP DOWN LEFT and RIGHT ARROW keys Version info displays the build the software version the database version the serial number and the total tests performed The utility keeps a permanent c...

Страница 22: ...nly continue when data card is entered IGNORE measurement is not stored and operator not no tified Display The LCD OPTIONS utility enables you to adjust the contrast of the text on the display and the...

Страница 23: ...See the SHOP utility for more information Format Card Select this utility to format a data card to receive data or erase all data on the card TheTester will warn you before formatting the card and as...

Страница 24: ...g the door to the battery compartment 3 Lift the door at the tab and place it aside 4 Remove the discharged batteries 5 Insert new batteries as shown make sure the positive and negative terminals are...

Страница 25: ...ting from extraneous causes including owner misuse Midtronics is not liable for any incidental or consequential damages for breach of this warranty The warranty is void if owner attempts to disassembl...

Отзывы: