background image

MAR-800P

Midtronics B.V.     Hoofdveste 6–8     Houten NL

www.midtronics.com

12

Chapter 4: Battery Test 

Additional Test Requirements and Messages

For a more decisive result the tester may ask for additional 

information or probe deeper into the battery’s condition. The 

following messages and instructions may appear before the 

analyzer displays the results of your test. 

System Noise

To perform a correct measurement the tester requires the 

vessel to be in rest. After the boat has sailed, some vessel 

specific systems might still be active in the background. 

The tester will detect this and displays the message 

SYSTEM NOISE. When this message appears switch off all 

consumers(radio, airconditioning) and remove the key from 

the ignition. As soon as there is no more activity in the vessel, 

the tester will continue testing and display the test result.

Unstable Battery Detected

A battery that is weak or that has just been charged may retain 

enough electrical activity to be detected by the analyzer 

and will adversely affect the test results. A fully charged 

battery should stabilize quickly, after which the analyzer 

will automatically retest. Weak batteries should be charged 

and retested. If the battery is fully charged, check the clamp 

connections.

Surface Charge

The battery can hold a surface charge if the engine has been 

running or after the battery has been charged. The tester may 

prompt you to remove the surface charge before it displays a 

test result.
1.  Follow the instructions indicating when to turn the head-

lights on and off (IN-VESSEL)

2.  The tester will resume testing after it detects that the sur-

face charge is removed.

Deep Scan Test

In some cases the tester may need to further analyze the 

battery to determine whether the battery should be replaced 

or it has a significant chance to be recovered. It will then 

conduct a Deep Scan Test of the battery for a few seconds.  

This test will typically be performed on batteries that are in a 

low state of charge.

Battery Test Results

After the test the tester will display the battery decisions with 
the complete results in a series of screens. Use the 

UP/DOWN 

ARROW

 keys to scroll through each result. To print the results 

press the 

PRINT

 soft key. To return to the Main Menu, press the 

END soft key.

Screen 1 of 2

Battery 

decision
Measured 

voltage

Selected 

rating

Battery 

temperature

Measured 

CCA 

Screen 2 of 2

Battery Decisions and Recommendations

Decision

Recommended Action

GOOD BATTERY

Return the battery to service.

GOOD–RECHARGE

Fully charge the battery and return it 

to service.

CHARGE & RETEST

Fully charge the battery and retest. 

Failure to fully charge the battery 

before retesting may cause false 

readings. 

If CHARGE REQUIRED 

appears again after you fully charge 

the battery, replace the battery.

REPLACE BATTERY

A REPLACE BATTERY result 

may also mean a poor connection 

between the battery and the vessel. 

If you tested the battery using the IN-

VESSEL test, disconnect the battery 

cables and retest using the OUT-OF-

VESSEL test before replacing it.

BAD CELL-REPLACE Replace the battery and retest.
FROZEN BATTERY

Thaw the battery and retest

24 VOLT SYSTEM

24-volt system detected. Connect to 

12V battery instead of the system.

Содержание MAR-800P

Страница 1: ...INSTRUCTION MANUAL Marine Battery Electrical Diagnostic Analyzer MAR 800P...

Страница 2: ...This page intentionally left blank...

Страница 3: ...d 12 Surface Charge 12 Deep Scan Test 12 Battery Test Results 12 New Battery Test Result 13 Pair Test Result 13 Pack Test Result 13 Chapter 5 System Test 14 Battery Test 14 Starter Test 14 Starter Sys...

Страница 4: ...losive mix of hydrogen gas and oxygen even when the battery is not in operation Always work in a well ventilated area Wash hands after handling REQUIRED BY CALIFORNIA PROP 65 Battery posts terminals a...

Страница 5: ...cable see the next page for detail Spring loaded data card slot for test data storage and software upgrades Infrared temperature sensor with a range of 28 C to 93 C 20 F to 200 F Data transmitter sen...

Страница 6: ...e of information requested The four types of entry methods are described below Typically the soft key below the right half of the screen confirms your choice although the word above it may vary In a s...

Страница 7: ...nd off The analyzer also turns on automatically when you connect its test leads to a battery Title Bar The title bar shows you the name of the current menu test tool utility or function Selection Area...

Страница 8: ...st counter and more UTILITY MENU includes functionality to setup the tester Print View Menu Icon Description BATTERY RESULTS displays the results of the last battery test performed and the totals by b...

Страница 9: ...test make sure all vessel accessory loads are off If systems in the vessel are still active it might lead to a SYSTEM NOISE message the tester will automatically continue to test the battery until the...

Страница 10: ...E AUXILIARY Battery Standards Rating System Description Range MCA Marine Cranking Amps 100 to 2000 EN A European Norm 100 to 2000 CCA Cold Cranking Amps specified by SAE The amount of current a batter...

Страница 11: ...2000 CCA Cold Cranking Amps specified by SAE The amount of current a battery can provide at 0 F 17 8 C 100 to 2000 JIS Japanese Industrial Standard shown on a battery as a combination of numbers and...

Страница 12: ...hen to turn the head lights on and off IN VESSEL 2 The tester will resume testing after it detects that the sur face charge is removed Deep Scan Test In some cases the tester may need to further analy...

Страница 13: ...frost the battery and retest 24 VOLT SYSTEM 24 volt system detected Connect to 12V battery instead of the system LOW VOLT REPLACE Battery voltage is too low Pair Test Result Decision Recommended Actio...

Страница 14: ...cases the tester may not detect the vessel s starting profile It will display the soft key options STARTED and NO START If you select STARTED the analyzer skips to the Alternator Test If you select NO...

Страница 15: ...Do not use cyclical loads such as air condi tioning 4 TESTING ALTERNATOR WITH LOADS ON The analyzer will determine if the charging system is able to provide suf ficient current for the demands of the...

Страница 16: ...ns from the alternator to the battery If the connection is loose or heavily corroded clean or replace the cable and retest HIGH VOLTAGE The voltage output from the alternator to the battery exceeds th...

Страница 17: ...the UP or DOWN ARROW key or use the LEFT or RIGHT ARROW key to move up or down four part numbers at a time Press the NEXT soft key to continue 3 Press an UP or DOWN ARROW key to select the BATTERY RAT...

Страница 18: ...est Chapter 7 Drain Test With the drain test you can check the amount of current that is lost as a result of leakage 1 Measure the drain current with the external amp meter 2 Enter the drain current a...

Страница 19: ...7 IEC 4 JIS 8 NONE Press the NEXT soft key to continue The BACK soft key returns you to the previous screen 4 Select the battery rating Press the UP and DOWN ARROW keys to select the rating In case o...

Страница 20: ...e UP DOWN LEFT and RIGHT ARROW keys The Print View Menu enables you to view and print the results of the last test performed Print View also allows you to view and print test decision totals To return...

Страница 21: ...fo using the UP DOWN LEFT and RIGHT ARROW keys Version info displays the build the software version the database version the serial number and the total tests performed The utility keeps a permanent c...

Страница 22: ...nly continue when data card is entered IGNORE measurement is not stored and operator not no tified Display The LCD OPTIONS utility enables you to adjust the contrast of the text on the display and the...

Страница 23: ...See the SHOP utility for more information Format Card Select this utility to format a data card to receive data or erase all data on the card TheTester will warn you before formatting the card and as...

Страница 24: ...g the door to the battery compartment 3 Lift the door at the tab and place it aside 4 Remove the discharged batteries 5 Insert new batteries as shown make sure the positive and negative terminals are...

Страница 25: ...ting from extraneous causes including owner misuse Midtronics is not liable for any incidental or consequential damages for breach of this warranty The warranty is void if owner attempts to disassembl...

Отзывы: