6a. Floodlight connection
6a. Floodlight connection
Inserting the terminal into the socket
Rotate the 3-pole terminal into the shown position to insert into the socket. Then push and rotate counter-clockwise
until you hear a click. The click means the terminal is properly locked into the socket.
Connect the plug and socket
Connect the plug to the socket. The arrow on the plug and the arrow on the socket must face each other.
Secure the connection
Rotate the outer part of the socket clockwise, then
push the red clip to the locked position to secure the
connection. If unlocking is required, use a screwdriver to
pull the clip to an unlocked position.
Warning
Do not pull the cables during installation. Do not bend the
cables more than the minimum bending radius - 5 to 8
times of the diameter of the cable.
Stripping the cable
Insert the cable through the connector housing.
The socket has L, N, earth symbols. Match as follows:
Live
BROWN wire
Neutral
BLUE wire
Earth symbol
YELLOW/GREEN wire.
Insert the exposed wires in the plug and tighten each
screw.
Pull the wires to check if they are well tightened
Tighten the nut
Tighten the plastic nut with a 24 mm wrench key.
midstreamlighting.com call +44 (0) 207 584 8310
10
11
MODUS S INSTALLATION GUIDANCE
SCALE 2:1
XSEC0001-XSEC0001
SECTION
CH 24 mm
Nm 2.5÷4
SCALE 1:2
SEE DETAIL
A