30
9
6a. Floodlight connection
Stripping the cable
Strip one end of the floodlight connection cable to a
length of circa 30 mm; then expose the conductors 9
mm.
(The cable from the driver to the floodlight is not supplied,
the cable used must be a rubber cable H05RN-F or
equivalent.)
The device has a type Y attachment. If it becomes
damaged it should only be replaced by the manufacturer
or by its service staff.
Take a TH405 Connector socket. The connector and its
housing are supplied in 2 pieces.
Adapting the grommet
Remove the inside part of the grommet, when the cable
diameter is greater than 9 mm. To remove the gasket,
remove cable gland nut first.
midstreamlighting.com call +44 (0) 207 584 8310
8
9
MODUS S INSTALLATION GUIDANCE
SCALE 1:1
SEE DETAIL
A
6a. Floodlight connection - outdoor driver
Unscrew the cover
Unscrew the 4 M5 screws. Then remove the plastic cap from the connector plug, push towards the connector side
and take away the cover.
Connecting via cable gland
Remove the 4 countersunk screws to remove the junction box lid. Insert the cable through the cable gland. If the
connection requires a shielded cable, replace the cable gland with an EMC M20x1.5 one (NOT included in the
package). Use monkey pliers to hold the M20 adapter if it is necessary to remove the cable gland. Remove the cable
sheath for 65 mm to connect the wires with ease. WARNING: do not unscrew or remove the M20 adapter!
M20 adaptor
Cable gland
Содержание Modus S 1100
Страница 1: ...Modus S Series INSTALLATION GUIDANCE v3 0...