background image

2

MODUS S INSTALLATION GUIDANCE

Contents

  24 mm standard wrench for M16 screws

  30 mm standard wrench for M20 screws

  #8 Allen key

  Powered drill-screwdriver with adjustable torque  

 (clutch)

  Torx T25 insert bit for powered screwdriver (to be  

 

used with M5 screws)

  Torx T25 manual screwdriver

  Torx T30 insert bit for powered screwdriver (to be  

 

used with M6 screws)

  Torx T30 manual screwdriver

  Monkey pliers

  Electrician scissors for wires

  Ph2 screwdriver

  Slotted manual screwdriver for connector’s screws  

 

(blade dimensions: 3.5(w) x 0.6(t)mm)

  Wire stripping pliers

DO NOT USE PERCUSSION DRILLS!

Equipment list

Prior to starting the installation, check the equipment list 
to be sure of using the correct tools (mounting screw(s) 
and nut(s) are not supplied).

 

Wear  adequate  working  gloves,  safety  shoes    and                                                                                                                                              

      hard hats to protect yourself from material dropping 

  Never  energize  the  lamp  if  wiring  operation  are                                                                                                                                              

      not completed

H&S check

Section  

PAGE

1   General notes 

3

2   Safety instructions 

4

3   Contents 

5

4   Bracket mounting and aiming  

6

Visor mounting 

7

Electrical connections 

7

6A   Floodlight connection 

8

6B   Power supply connection 

13

6C   Control connection 

15

6D    Cabinet Driver                                                       17

Electrical specifications 

18

Weight and Windage 

18

9      Dimensions  

19

1. General notes

This user manual contains important information on safe operation of the Luminaire.

Read and follow all safety notes and all instructions. Save this manual for future reference.

Make sure that it is available to all persons using this device.  
All wiring should be done by a licensed electrician in accordance with state codes, local codes, and National  
Electric Code (NEC) standards or International Electro  
technical Commission (IEC) standards.

The Luminaire is suitable for wet locations.

This luminaire has to be replaced only by the manufacturer, by its service staff or by qualified personnel.

The luminaire is suitable for outdoor use

IP66:

 The product is protected against powerful water jets.

DO

 

Store  the  Luminaire  with  care,  avoiding  placing  the  lenses  to  the  ground  which  may  scratch  or  damage                                                                                                                                           

       them

 

To avoid damaging the Luminaire, keep it in the original packaging when storing

 

When handling the Luminaire, wear industrial safety gloves and safety boots

 

Operate on circuitry when the electrical power supply is disconnected

DO NOT

 

Apply  mains  voltage  through  the  control  system  cable.  This  will  damage  the  luminaire  that  will  no  longer  be                                                                                                                                               

       covered by warranty

 

Unnecessarily remove the Luminaire from the box

 

Leave the LED Luminaire switched on when rested on the ground with optics facing down

 

Place the Luminaire with the lens on the pavement, dirt and metal surfaces

 

Clean the lenses with any industrial detergent, but with water-soaked cloth if needed

midstreamlighting.com   call +44 (0) 207 584 8310

3

Содержание Modus S 1100

Страница 1: ...Modus S Series INSTALLATION GUIDANCE v3 0...

Страница 2: ...important information on safe operation of the Luminaire Read and follow all safety notes and all instructions Save this manual for future reference Make sure that it is available to all persons using...

Страница 3: ...d experience may use this device The minimum safety distance from illuminated object to avoid any damages is 1 m midstreamlighting com call 44 0 207 584 8310 5 Modus S LED floodlight Remote driver x1...

Страница 4: ...ped with an angled bracket that has a central hole for an M20 screw tightening torque 250 Nm and two slots for M16 screws tightening torque 150 Nm 3 Adjusting angle The LED Luminaire can be tilted for...

Страница 5: ...he gasket remove cable gland nut first midstreamlighting com call 44 0 207 584 8310 8 9 MODUS S INSTALLATION GUIDANCE SCALE 1 1 SEE DETAIL A 6a Floodlight connection outdoor driver Unscrew the cover U...

Страница 6: ...the connection If unlocking is required use a screwdriver to pull the clip to an unlocked position Warning Do not pull the cables during installation Do not bend the cables more than the minimum bend...

Страница 7: ...the mains cable through the cable gland without the adapter Connect the YELLOW GREEN wire to the 5 way WAGO terminal Close the void position as well even if there is no wire connected Connect the BRO...

Страница 8: ...he cover back on to the driver unit and the cap on the control plug if not needed Strip the rubber jacket of the cable expose 25 mm of conductors Mount the TH384 socket connector Match L RED conductor...

Страница 9: ...DUS S INSTALLATION GUIDANCE 25 Dim Dim 12v Outdoor layout INPUT cable this cable power supplies the driver Its 3 wires have to match these connections Brown L L1 Blue N L2 Yellow Green Ground OUTPUT c...

Страница 10: ...er Weight 20kg 9kg 6 5kg Windage 0 203m2 at 220 V ac input 25 C cold start 10 Ipk 10 Ipk Modus S Floodlight Modus S Outdoor driver cabinet driver is the same without metalwork 280 x 230 x 76 mm midstr...

Страница 11: ...ation guides European HQ Midstream Ltd Wessex House 1 Chesham Street London SW1X 8ND United Kingdom Telephone 44 207 584 8310 Email info midstreamlighting com US HQ Midstream Lighting Ltd 66 West Flag...