HARDWARE ALIGNMENT
The following procedures assume a good quality dedicated line is being used and the tone remote adaptor is already
installed. The alignments are preset at the factory and should not need to be adjusted during installation. However, if an
adjustment is needed, please follow the procedures below.
RX Input Line Level Adjustment:
1. With the dedicated line connected to the TRC, connect a line level meter to the red and green (or yellow & black
with the 4-wire option) in bridging mode. If testing on a bench with no tone remote adaptor available use termination
mode on the line level meter.
2. With the line level meter generating Low-Level Guard Tone at -20 dBm, monitor TP304 with an oscilloscope.
3. Adjust RP306, so that 200 mV p-p is seen at TP304 or 165 mV p-p is seen at TP301. If paralleling multiple remotes,
this alignment should be done with all remotes attached.
TX Output Line Level Adjustment:
1. With the dedicated line connected to the TRC, connect a line level meter to the red and green in bridging mode. If
testing on a bench with no tone remote adaptor available use termination mode on the line level meter.
2. Set RP201 to 90%.
3. Push and hold the SEND key on the TRC to generate the Low-Level Guard Tone.
4. Adjust RP202 so that the line level meter shows the Low-Level Guard Tone at -20 dBm. If paralleling multiple
remotes, this alignment should be done with all remotes attached.
RX Notch Filter Alignment:
1. Generate the 2175 Hz Low-Level Guard Tone to the TRC.
2. Turn RP303 fully clockwise.
3. Monitor TP303 with a Sinadder. The sensitivity of the Sinadder should be adjusted to hear the tone.
4. Adjust RP302 until the tone is at it’s most diminished point.
5. Adjust RP303 until the tone fully diminishes.
6. Repeat steps 4 and 5 until no tone remains.
TX Notch Filter Alignment:
1. Unplug the internal microphone from the TRC, install JP101 1-2 and turn RP102 fully clockwise.
2. Push and hold the SEND key on the TRC to generate the 2175 Hz Low-Level Guard Tone.
3. Monitor TP103 with a Sinadder. The sensitivity of the Sinadder should be adjusted to hear the tone.
4. Adjust RP103 until the tone is at it’s most diminished point.
5. Adjust RP102 until the tone fully diminishes.
6. Repeat steps 4 and 5 until no tone remains.
7. After aligning the TX notch filter, remove JP101 and plug back in the internal or gooseneck microphone.