21
CONSOLE SETUP menu <5>
Data Entry Mode:
Determines if numeric entry or alphanumeric data entry is the default mode when placing a
call. The mode of entry can also be toggled by pressing the MENU key during data entry. Enable
alphanumeric mode only after entering names and numbers in the user database.
NUMERIC
Start in numeric only mode.
ALPHA
Start entry in alphanumeric mode.
Func Display:
Turning on this option causes the last selected function to be displayed every 2 seconds on
the bottom line of the display when in Control Mode. This option applies only when there is a distinction
between frequency and function in your application.
OFF
Disable function display.
ON
Enable function display.
Ignore Nonuser:
Turning on this option helps prevent the display of false decodes by ignoring ID’s which do
not appear in the user database.
OFF
Display ID’s not in database.
ON
Ignore ID’s not in database.
Fast Scrolling:
Fast Scrolling allows for faster navigation through the menu system. When this setting is
turned off, menu items will appear to scroll from side-to-side. This provides positive feedback in response to
scrolling through menus and the ANI log. If this effect is desired, Fast Scrolling can be disabled.
OFF
Scroll slowly to give side-to-side effect.
ON
Scroll at fast speed.
Contrast :
Allows the display contrast to be adjusted for best viewing.
LOW
Low contrast setting.
HIGH High
contrast
setting.
Timeout Timer:
Prevents the transmitter from being keyed indefinitely if the SEND key is stuck or
unintentionally in the depressed position. The TRC will cease sending low-level guard tone and disable the
line driver after the amount of time programmed by this setting. This timer also applies to the INTER key. If set
to 00, the timeout timer feature will be disabled. Both digits must be entered.
Range:
00 to 99 seconds
Default: 00
seconds
Microphone:
Selects which type of microphone is attached to the TRC. Be sure to set jumpers accordingly.
INT/GOOSENECK
Internal or gooseneck style microphone.
HANDSET External
handset.
Off-hook Mon:
If enabled, the TRC will automatically transmit the Monitor Function sequence as per FCC
requirements when the operator picks up an externally attached handset. For privately owned systems this
option can be disabled. The External Handset Option must be enabled for this setting to be recognized.
OFF
Do not transmit the monitor sequence when the handset goes off-hook.
ON
Automatically transmit the monitor sequence when the handset goes off-hook.
Line 2/Sup Opt:
If the line-2/supervisor relay is installed, this setting must be enabled for the feature to work.
OFF
Line 2 or supervisor option disabled.
ON
Line 2 or supervisor option enabled.
Printer Option:
The TRC, if ordered with the printer cable option, can log the ANI traffic to a serial printer or
computer. The printer must have a print buffer and a standard RS-232 port. It must be configured for 9600
baud, 8 data bits, 1 stop bit and no parity. In order to send data to the printer, this option must be on.
OFF
Do not send data to printer.
ON
Send data to printer.