Service manual for Wash and Dry Combo product
Midea America Company
-------------------------------------------------------------------------------------------------------------------------------------------------------
-
23
-
Port definition
Port
Name on PCB
Definition
1
CN1-1
CN1-2
CN1-3
CN1-1: DISPENSER MOTOR_L
CN1-2: HOT_VALVE _L
CN1-3: COLD_VALVE_1 _L
2
CN2-1
CN2-2
CN2-3
CN2-1:
Water sensor 1
CN2-2:
Water sensor GND
CN2-3:
Water sensor 2
3
CN3-1
CN3-2
CN3-3
CN3-4
CN3-1:
PUMP RTN
CN3-2:
NEUTRAL
CN3-3:
DOOR LOCK LINE
CN3-4:
STEAM RETURN
4
CN4-1.
CN4-2
CN4-3
CN4-4
CN4-1:
COLD_VALVE_3 RTN
CN4-2:
MOTOR_N
CN4-3:
WATER VALVE RETURN
CN4-4:
STEAM RETURN
5
CN5-1
CN5-2
CN5-1:
DOOR LOCK OUT
CN5-2:
HTR_N
6
CN7-1
CN7-2
CN7-3
CN7-4
CN7-5
CN7-1:
Pwr_12V
CN7-2:
TXD
CN7-3:
RXD
CN7-4:
GND
CN7-5:
TACHO
7
CN8-1
CN8-2
CN8-3
CN8-4
CN8-5
CN8-6
CN8-1:
C_VALVE_3_L
CN8-2:
FAN_L
CN8-3:
DRAIN_L
CN8-4:
STEAM_L
CN8-5:
HTR_L
CN8-6:
MOTOR_L
8
CN11-1
CN11-2
CN11-3
CN11-4
CN11-1:
Thermistor 5V
CN11-2:
T
hermistor_1
CN11-3:
Thermistor 5V
CN11-4:
Thermistor_2
9
CN13-1
CN13-2
CN13-3
CN13-4
CN13-1:
Thermistor 5V
CN13-2:
Thermistor_3
CN13-3:
DISPENSER_A
CN13-4:
DISPENSER_B