Blower Plate
Blower Motor
Screw
Back of
Microwave
31
7. Remove the knockout plates in the back of the unit with snips. (For some models)
8. Place the blower unit back into the opening.
CAUTION: Do not pull or stretch the blower unit wiring. Make sure the wires are not
pinched, and that they are properly secured.
NOTE: The blower unit exhaust openings should match exhaust openings on rear of
microwave oven.
9. Secure the blower unit to the microwave with the original screw.
Back of mircrowave
Knockout Plates:
Snip all 4 webs on
each knockout panel
and remove the metal
knockouts for rear airflow.
Please take care to
remove any sharp edges
created from removing
the knockout plates.
AFTER: Fan Blade
Openings Facing Back
End A
End B
10. Replace the blower plate in the same position as before with the screw.
Make sure the screw is tight.
Push in securely until it is in the lower locking tabs. Take care to assure that the damper
hinge is installed so that it is at the top and that the damper swings freely.
11. Attach the exhaust adaptor to the rear of the oven by sliding it into the guides at the top
center of the back of the oven.