MCAC-RTSM-2011-12
Midea Combo Type Heat Pump Water Heater Technical Manual
36
d) Vacation Mode: After pressing
"Vacation
" button, the unit will automatically heat water to 15
℃
for
the purpose of energy saving during vacation days.
e) Disinfect Mode: After pressing "
Disinfect
" button, the unit immediately start to heat water up to
65
℃
to kill the potential legionella bacteria inside water of tank.
2.2.3.5 Temperature Setting
Temp displayed is the water temp. in the upper part of the tank. Default is 55
℃
.
Method for set.
2.2.3.6 TIMER
User can set up a running start time and a stop time on a specifically by the timer function. The least
numbers of timer is ten minutes. Time on: User can set up a start time by this. The unit will auto run one time
between the set time and 24:00 on the same day.
Method for set.
Содержание RSJ-15/190RDN3-D
Страница 12: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 12 Model RSJ 35 300RDN3 D...
Страница 14: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 14 5 Service Space...
Страница 16: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 16 Model RSJ 35 300RDN3 D...
Страница 17: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 17 7 Piping Diagrams...
Страница 21: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 21 Model RSJ 35 300RDN3 D...
Страница 28: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 28 Model RSJ 35 300RDN3 D...