MCAC-RTSM-2011-12
Midea Combo Type Heat Pump Water Heater Technical Manual
39
7) Correct earthing;
8) Correct power supply;
9) No obstacle outside the air inlet and outlet;
10) No air in the water pipeline and all valve opened;
11) Effective electric leakage protector;
12)
Sufficient inlet water pressure(≥0.15MPa)
2.4 Refrigerant figure
2.4.1 System Piping figure
Model : RSJ-15/190RDN3-D
Compressor :
GMCC PJ125G1C-4DZDE, R134a compressor
;
ATCO (Temp. Switch):
If the water temperature is too high. If the temperature is higher than 78
℃
, the
ATCO will automatically shut off the power of compressor and E-heater, and turn on it if the temperature
fall down below 68
℃
;
TCO (Temp. Switch)
:
If the water temperature is higher than 85
℃
, the TCO will automatically shut off
the power of compressor and E-heater, it must be re-turn on manually.
High Pressure Switch
: switch OFF when 2.76MPa; switch ON when 2.07MPa;
Fan
: Centrifugal type, 220V
—240V/50Hz
,
3 Speeds;
Содержание RSJ-15/190RDN3-D
Страница 12: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 12 Model RSJ 35 300RDN3 D...
Страница 14: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 14 5 Service Space...
Страница 16: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 16 Model RSJ 35 300RDN3 D...
Страница 17: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 17 7 Piping Diagrams...
Страница 21: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 21 Model RSJ 35 300RDN3 D...
Страница 28: ...MCAC RTSM 2011 12 Midea Combo Type Heat Pump Water Heater Technical Manual 28 Model RSJ 35 300RDN3 D...