GD  Midea  Refrigeration  Equipment  Co.  Ltd                                                                      Service  manual  for  K  portable  Series 

No power 

Check voltage at electrical outlet. Correct if none. 

Water alarm

 

Check and correct if water alarm happens.

 

Power supply cord

 

Check voltage at the power cord terminal on Main PCB. Replace 

the power cord if none.

 

Transformer (Discharge 

transformer before testing)

 

Check resistance between the two input/output lines on 

transformer. Replace the transformer if either of the input/output 

is open or the transformer is damaged.

 

Wire disconnected or 

connection loose

 

Connect wire. Refer to wiring diagram for terminal identification. 

Repair or replace loose terminal.

 

Main PCB failure

 

Select fan speed and Check the voltage on main PCB. Replace 

the main PCB if no voltage in anyone.

 

Capacitor (Discharge 

capacitor before testing)

 

Test capacitor.                                              

Replace if not /-10% of manufacture's rating. Replace if 

shorted, open or damaged.

 

Fan motor will not 

run. 

Will not rotate

 

Fan blower hitting scroll. Realign assembly.                                         

Check fan motor bearings. Replace the motor if motor shaft do 

not rotate.

 

Fan blower 

Replace the fan blower if cracked, out of balance, or partially 

missing. 

Loose screws

 

Tighten them.

 

Fan motor noise. 

Worn bearings

 

Replace the motor if knocking sounds continue when running or 

loose, or the motor hums or noise appears to be internal while 

running.

 

Voltage 

Check voltage. Call Supply Authority if not within limits. 

Wiring

 

Check the wire connections, if loose, repair or replace the 

terminal. If wires are off, refer to wiring diagram for identification, 

and replace. Check wire locations. If not per wiring diagram, 

correct.

 

Main PCB failure

 

Check voltage of main PCB. Replace the main PCB if open.

 

Capacitor (Discharge 

capacitor before testing)

 

Check the capacitor.                                                                                 

Replace if not /-10% of manufacturers rating. Replace if 

shorted, open, or damaged. 

 

Room temp sensor

 

Check the temperature setting if not at the coolest (in cooling 

mode) or the warmest (in heating mode). Set it if not. 

 

Compressor will not 

run while fan motor 

runs. 

Compressor

 

Check the compressor for open circuit or ground. If open or 

grounded, replace the compressor.

 

Excessive noise. 

Copper tubing 

Remove the cabinet and carefully rearrange tubing not to contact 

cabinet, compressor, shroud and barrier. 

Water tank full 

Check and pour if the water tank is full. 

Water depth sensor if failure

Check and replace if failure.

 

Water pump failure

 

Check and replace if the pump if failure.

 

Water depth is over load in 

chassis

 

Check and drainage the water in the chassis by open the 

drainage hose on the chassis.

 

Water full alarm 

Water depth sensing 

structure

 

Check and replace or realign if the structure is failure.

 

Содержание PK-09ER

Страница 1: ...MPK 09ERN2 MPK 10CEN2 MPK 10CRN2 MPK 10EEN2 MPK 10ERN2 MPK 12CEN2 MPK 12CRN2 MPK 12EEN2 MPK 12ERN2 MPK 08CE MPK 08CR MPK 08EE MPK 08ER MPK 09CE MPK 09CR MPK 09EE MPK 09ER MPK 10CE MPK 10CR MPK 10EE M...

Страница 2: ...tem The refrigerant was charged at the factory Be sure to read the safety precautions prior to servicing the unit 1 1 SAFETY PRECAUTIONS 1 When servicing the unit set the POWER SWITCH to OFF and unplu...

Страница 3: ...1 4 CONTROL LOCATIONS For cooling only with electric heater models For cooling only models Remote receiver Timer ON button Push this button to set the Timer On time Timer OFF button Push this button t...

Страница 4: ...button except this button Reset button Press this button to reset all settings to factory settings 2 TROUBLESHOOTING GUIDE 2 1 REFRIGERATION CYCLE DIAGRAM 2 2 ELECTRICAL FUNCTION 2 2 1 Electric Contr...

Страница 5: ...ot operate After the problem is cleared the unit will be ready to operate But if you push the power button the unit will shut the P1 display and shut down 2 2 5 Fan only Mode Function Requirement 2 2...

Страница 6: ...the other is called the Structure Damage ROOM AIRCONDITIONER VOLTAGE LIMITS NAMEPLATE RATING MINIMUM MAXIMUM 220 240V 115V 196V 103V 253V 122V PROBLEM POSSIBLE CAUSE REMEDY Power failure Check the po...

Страница 7: ...nocking sounds continue when running or loose or the motor hums or noise appears to be internal while running Voltage Check voltage Call Supply Authority if not within limits Wiring Check the wire con...

Страница 8: ...utlet valve of the compressor is damaged making the low pressure connected with the high pressure The refrigerating system can not produce high pressure and low pressure Replace the compressor after c...

Страница 9: ...N2 MPK 10CE MPK 10CR MPK2 09CEN1 QB6 MPK2 09CRN1 QB6 MPK2 10CEN1 QB6 MPK2 10CRN1 QB6 MPK2 12CEN1 QB4 MPK2 12CRN1 QB4 MPK2 12CE QB6 MPK2 12CR QB6 3 2 FOR COOLING AND HEATING MODELS MPK 09EEN2 MPK 09ERN...

Страница 10: ...GD Midea Refrigeration Equipment Co Ltd Service manual for K portable Series 9 3 3 ELECTRICAL CONTROL SCHEME...

Страница 11: ...GD Midea Refrigeration Equipment Co Ltd Service manual for K portable Series 10...

Страница 12: ...GD Midea Refrigeration Equipment Co Ltd Service manual for K portable Series 11 3 4 MAIN CONTROL BOARD SCHEME...

Страница 13: ...GD Midea Refrigeration Equipment Co Ltd Service manual for K portable Series 12 3 5 DISPLAY BOARD SCHEME...

Страница 14: ...ord and disconnect the Air pipe from rear of the unit Move the unit to a replace where water can be poured Remove the rubber plug from back of the unit and drainage the water in from the unit Remove t...

Страница 15: ...ssemble the display board assembly just push the clasp and release the assembly Now it is easy to replace the display board Take care to release the connector which connected to the display board 4 4...

Страница 16: ...t for reference when wiring Pay attention to the wires in the enclosure 1 2 3 4 5 6 7 8 9 10 1 Terminate to display board 2 Terminate to condenser fan motor 3 Out put of transformer 4 Terminate to eva...

Страница 17: ...ws fixing the air out frame Lift the frame up then pull the frame forward Remove the screws fixing the fan shell box Remove the fan motor fan scroll and blower wheel from the unit Take care to the wir...

Страница 18: ...emove the screws fixing the evaporator Remove the screws fixing the condenser fan motor bracket Then remove the bracket with condenser fan motor and blower wheel from the unit 4 9 To repair the refrig...

Страница 19: ...rom the cover Then remove the condenser fan scroll Now it is easy to repair the refrigerant system 4 10 To repair the water disposal system or replace the water depth switch or the pump Remove the scr...

Страница 20: ...ve the screw fixing the water switch which controls the water in tank Press the clamp fixing the water switches which control the water in the chassis Press downward here Then remove the screws fixing...

Страница 21: ...GD Midea Refrigeration Equipment Co Ltd Service manual for K portable Series 20 5 Exploded view See attached files 6 Spare parts list See attached files 7 Specification See attached files...