Display Board & Fault Codes
8.1 Indoor Unit Error Display
Operation
lamp
Timer lamp Display LED STATUS
1 time
X
E0
Indoor unit EEPROM parameter error
2 times
X
E1
Indoor / outdoor units communication error
4 times
X
E3
Indoor fan speed has been out of control
5 times
X
E4
Indoor room temperature sensor T1 open circuit or short
circuit
6 times
X
E5
Evaporator coil temperature sensor T2 open circuit or
short circuit
7 times
X
EC
Refrigerant leakage detection
1 times
O
F0
Overload current protection
2 times
O
F1
Outdoor ambient temperature sensor T4 open circuit or
short circuit
3 times
O
F2
Condenser coil temperature sensor T3 open circuit or
short circuit
4 times
O
F3
Compressor discharge temperature sensor T5 open
circuit or short circuit
5 times
O
F4
Outdoor unit EEPROM parameter error
6 times
O
F5
Outdoor fan speed has been out of control
1 times
P0
IPM malfunction or IGBT over-strong current protection
2 times
P1
Over voltage or over low voltage protection
3 times
P2
High temperature protection of compressor top
diagnosis and solution
5 times
P4
Inverter compressor drive error
O light X off
flash
Page
34
13
Содержание MOB01-09HFN8-QRD6GW
Страница 1: ...Installation Manual Mission Series R410a Models R32 Models...
Страница 6: ...Page 6 Installation Overview 3 Unit Installation Overview INSTALLATION ORDER...
Страница 8: ...Page 8 Indoor Unit Installation 4...
Страница 10: ...Page 10 Indoor Unit Installation 4...
Страница 14: ...For MOCA02 24HFN1 QRD0GW Page 14 Outdoor Unit Installation Instructions...
Страница 16: ...Drainpipe Installation 6 Page 16...
Страница 39: ...17 Old Park Lane London W1K 1QT Tel 44 0 2074 092009...