b. Using wire strippers, strip the rubber jacket from
both ends of signal cable to reveal about 15cm
c. Strip the insulation from the ends of the wires.
d. Using a wire crimper, crimp u-lugs on the ends of
the wires.
NOTE:
While connecting the wires, please strictly follow
the wiring diagram (found inside the electrical box cover).
2. Remove the electric cover of the outdoor unit.
If there is no cover on the outdoor unit, disassemble
the bolts from the maintenance board and remove the
protection board. (See Fig. 8.1, 8.2)
Cover
Screw
Fig. 8.1
3. Connect the u-lugs to the terminals
4. Clamp down the cable with designated cable clamp.
5. Insulate unused wires with electrical tape. Keep them
away from any electrical or metal parts.
6. Reinstall the cover of the electric control box.
Indoor Unit Wiring
1. Prepare the cable for connection
a. Using wire strippers, strip the rubber jacket from
both ends of signal cable to reveal about 15cm
b. Strip the insulation from the ends of the wires.
c. Using wire crimper, crimp the u-lugs to the ends of
the wires.
2. Open the front panel of the indoor unit. Using a
screwdriver, remove the cover of the electric control box
on your indoor unit.
3. Thread the power cable and the signal cable through
the wire outlet.
4. Connect the u-lugs to the terminals.
Connective wiring diagram
Wiring diagram
CAUTION
•
While connecting the wires, please strictly follow
the wiring diagram.
•
The refrigerant circuit can become very hot. Keep
the interconnection cable away from the copper
tube.
5. Clamp down cable with the designated cable clamp to
secure it in place. The cable should not be loose, and
6. Reinstall the electric box cover and the front panel of
the indoor unit.
Wiring
Fig. 8.4
of the wires inside.
of the wires inside.
should not pull on the u-lugs.
Terminal block
Wire cover
Screw
Cable clamp
Match the wire colo
u
rs/labels with the labels on the
terminal block, and firmly screw the u-lug of each
wire to its corresponding terminal. Refer to the Serial
Number and Wiring Diagram located on the cover of
the electric control box.
Match the wire colo
u
rs/labels with the labels on the
terminal block, and firmly screw the u-lug of each wire
to its corresponding terminal.
Page
21
Содержание MOB01-09HFN8-QRD6GW
Страница 1: ...Installation Manual Mission Series R410a Models R32 Models...
Страница 6: ...Page 6 Installation Overview 3 Unit Installation Overview INSTALLATION ORDER...
Страница 8: ...Page 8 Indoor Unit Installation 4...
Страница 10: ...Page 10 Indoor Unit Installation 4...
Страница 14: ...For MOCA02 24HFN1 QRD0GW Page 14 Outdoor Unit Installation Instructions...
Страница 16: ...Drainpipe Installation 6 Page 16...
Страница 39: ...17 Old Park Lane London W1K 1QT Tel 44 0 2074 092009...