Quick Step Installation Guide
Mission High Wall Quick Step Installation Guide
Step 1:
Prior to unpacking equipment please inspect boxes for any transport damage to ensure products are in perfect condition.
Step 2
: Ensure the equipment model numbers on the boxes correspond with your companies purchase order.
Step 3:
Unpack the equipment and ensure all parts are accounted for i.e Indoor / Outdoor & Infra-red Controller.
Step 4:
Store the Infra-red service controller safely as this can be used to speed up commissioning and servicing process.
Step 5:
Review the installation and maintenance manuals which are provided.
Step 6:
Carry out the positioning and installation of indoor and outdoor units as per guidelines within the installation manual.
Step 7:
Install refrigerant pipework (Purge with OFN while brazing), electrical wiring & drainage pipe work.
Step 8:
Power & Interconnecting control wiring between indoor and outdoor units is made by linking into terminals W-1(L)-2(N)-S-E.
Step 9:
Pressure test pipework (Note do not carry out pressure test while connected to outdoor unit to prevent contamination of factory charge)
(1) Strength test in 5 Bar increments up to full test pressure. (2) Then leak test at lower pressure. Evacuate system to 2 torr or lower for appropriate time.
Step 10:
If required please add additional refrigerant charge (see table on reverse).
Step 11:
Carry out all the commissioning checks required to activate the warranty of the newly installed system.
Step 12:
Perform the test operation in accordance with the installation manual to ensure all functions and parts are working correctly.
Step 13:
Complete your warranty card document and e-mail this with dated photo of outdoor serial number to:
Note:
Installation videos can also be found on the Midea UK YouTube channel.
Please contact your Midea support team if you have any issues during the installation and commissioning process.
Tel:
02074 092009
E-Mail:
Indoor
Model
Outdoor
Model
Cooling Duty
(Kw)
Heating Duty
(Kw)
Outdoor Dimensions
Outdoor Weight
(Kg)
Indoor Dimensions
Indoor
Weight(Kg)
W(mm) D(mm) H(mm)
W(mm) D(mm) H(mm)
MSMBAU-09
MOBA02-09
3.3
3.75
770
300
555
27.1
730
198
293
7.4
MSMBAU-12
MOBA02-12
4.5
4.9
800
333
554
29.7
810
200
300
8.2
MSMBAU-18
MOBA02-18
6.2
6.8
800
333
554
37.2
980
225
335
10.5
MSMBAU-24
MOBA02-24
8.1
9.3
845
363
702
48.5
1090
235
338
12.9
Piping Information
Model:
09
12
18
24
Liquid Line
Inch
1/4
1/4
1/4
3/8
Gas Line
Inch
3/8
3/8
1/2
5/8
Drain Line
Φ mm
16
16
16
16
Max Length
M
25
25
30
50
Max Height
M
10
10
20
25
Electrical Wiring Information
Model:
09 12 18
24
Mains Outdoor
3x1.5mm²
3x2.5mm²
Interconnecting/Indoor Power
5x1.5mm²
5x2.5mm²
Power Supply Information
Model:
09
12
18
24
Outdoor
Ph/A
1/16
1/16
1/16
1/20
Indoor
Powered from Outdoor Unit
Refrigerant Charging Information
Model:
09
12
18
24
Pre – Charge
Kg
0.8
0.95
1.48
2.0
Charged to
M
5
5
5
5
Additional
g/m
15
15
15
30
Refrigerant
Type
R410A
Wi Fi Control Available as Standard
Page
33
12
Содержание MOB01-09HFN8-QRD6GW
Страница 1: ...Installation Manual Mission Series R410a Models R32 Models...
Страница 6: ...Page 6 Installation Overview 3 Unit Installation Overview INSTALLATION ORDER...
Страница 8: ...Page 8 Indoor Unit Installation 4...
Страница 10: ...Page 10 Indoor Unit Installation 4...
Страница 14: ...For MOCA02 24HFN1 QRD0GW Page 14 Outdoor Unit Installation Instructions...
Страница 16: ...Drainpipe Installation 6 Page 16...
Страница 39: ...17 Old Park Lane London W1K 1QT Tel 44 0 2074 092009...